Indoor unit
Model name
type
ASYG07KGTB
ASYG09KGTB
ASYG12KGTB
ASYG14KGTB
ASYG18KMTB
ASYG22KMTB
ASYG24KMTB
ASYG07KMTB
ASYG09KMTB
ASYG12KMTB
Wall mounted
ASYG14KMTB
ASYG07KMCC
ASYG09KMCC
ASYG12KMCC
ASYG14KMCC
ASYG07KETA
ASYG07KETA-B
ASYG09KETA
ASYG09KETA-B
ASYG12KETA
ASYG12KETA-B
ASYG14KETA
ASYG14KETA-B
ABYG18KRTA
Ceiling
ABYG22KRTA
AGYG09KVCA
AGYG12KVCA
Floor
AGYG14KVCA
*: Printed Circuit Board
PCB* fuse
Fan motor thermal protector
Activate: 110 ±15 °C
Fan motor speed down
Reset: 110 ±15 °C
Fan motor speed recover
Activate: 125 ±10 °C
Fan motor stop
Reset: 100 ±10 °C
Fan motor restart
Activate: 125 ±10 °C
Fan motor stop
Reset: 100 ±10 °C
Fan motor restart
Activate: More than 95 °C
Fan motor speed down
Reset: 95 °C or less
Fan motor speed recover
Activate: 125 ±10 °C
250 V, 3.15 A
Fan motor stop
Reset: 100 ±10 °C
Fan motor restart
Activate: 170
Fan motor stop
Reset: 145
Fan motor restart
Activate: 110 ±15 °C
Fan motor speed down
Reset: 110 ±15 °C
Fan motor speed recover
Activate: 125 ±10 °C
Fan motor stop
Reset: 100 ±10 °C
Fan motor restart
250 V, 3.15 A
Activate: 135 ±15 °C
Fan motor stop
Reset: 105 ±15 °C
250V, 5.0 A
Fan motor restart
Activate: 150 ±15 °C
Fan motor stop
250V, 5.0 A
Reset: 120 ±15 °C
Fan motor restart
- 149 -
Terminal
thermal
fuse
102 °C Off
+25
°C
-30
+25
°C
-30
102 °C Off
108 °C Off
110 °C Off
Float
switch
10. Safety devices