15) Press the <ENTER> button.
f The specified [MODE] and [LINK] is enabled. Afterwards, if [CALIBRATION MESSAGE] is [ON], messages during calibration is
displayed. The display automatically disappears 30 seconds after calibration has been completed.
f If the <ENTER> button is pressed with [MODE] in [BRIGHTNESS CONTROL SETUP] set to other than [OFF], the light source
brightness at the time the button was pressed is recorded as the standard brightness.
f If the <ENTER> button is pressed when [LINK] is set from [GROUP A] to [GROUP D], the group name is displayed on the screens of
projectors that have been set in the same group.
Note
f When [MODE] in [BRIGHTNESS CONTROL SETUP] is running with [AUTO] or [PC], the light source brightness is automatically
measured 15 minutes after the light source lights up, and correction is performed so that the screen brightness will be the same as the
standard brightness when the brightness control is adjusted. Brightness is not measured since the light source brightness is not stable for
approximately 15 minutes after the light source lights up.
f When [MODE] of [BRIGHTNESS CONTROL SETUP] is running in [AUTO] and [LINK] is [OFF], the brightness will be corrected until it
reaches the maximum amount of correction.
f The variation in brightness may increase due to dust accumulating on the lens, screen, or inside the projector, depending on the installation
environment of the projector.
f When the variation in brightness has increased due to the deterioration of the light source over time, or when you replaced the light source
unit, readjust the brightness control.
f When the projector is used continuously for more than 24 hours, set the [CALIBRATION TIME] in [BRIGHTNESS CONTROL SETUP]. If it is
not set, correction will not be performed automatically.
f The brightness control and the ECO management operate simultaneously. However, [LIGHT POWER] in [ECO MANAGEMENT] is fixed to
[NORMAL] while the brightness is measured. Also, [AUTO POWER SAVE] is fixed to [OFF].
f The set changes in the [CALIBRATION TIME] will be reflected during the time you entered.
f The set changes in the [CALIBRATION MESSAGE] will be reflected at the time items are switched using qw.
Setting [BRIGHTNESS CONTROL STATUS]
Display the brightness control status.
1)
Press as to select [BRIGHTNESS CONTROL].
2)
Press the <ENTER> button.
f The [BRIGHTNESS CONTROL] screen is displayed.
3)
Press as to select [BRIGHTNESS CONTROL STATUS].
4)
Press the <ENTER> button.
f The [BRIGHTNESS CONTROL STATUS] screen is displayed.
[BRIGHTNESS CONTROL STATUS] screen display example
When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to
[OFF]
The screen shows the status that the brightness control is disabled.
BRIGHTNESS CONTROL STATUS
MODE
PROJECTOR
RETURN
MENU
Chapter 4 Settings — [PROJECTOR SETUP] menu
LINK
OFF
1
GROUP A
When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to
[AUTO] and [LINK] is set to [OFF]
The screen shows the status of the brightness control in one
projector
BRIGHTNESS CONTROL STATUS
LINK
PROJECTOR
RETURN
MENU
OFF
1
5
6
ENGLISH - 81