Control Board Model Code Setting - Hoshizaki IM-500SAB Service Manual

Stackable square cuber
Hide thumbs Also See for IM-500SAB:
Table of Contents

Advertisement

E. Control Board Model Code Setting
1. Control Board Replacement
• This appliance should be diagnosed and repaired only by qualified service
personnel to reduce the risk of death, electric shock, serious injury, or fire.
• Move the control switch to the "OFF" position and turn off the power supply. Place
the disconnect in the "OFF" position. Lockout/Tagout to prevent the power supply
from being turned back on inadvertently.
1) Move the control switch to the "OFF" position and turn off the power supply. Place the
disconnect in the "OFF" position. Lockout/Tagout to prevent the power supply from
being turned back on inadvertently.
2) Remove the front cover and control box cover.
3) Disconnect all the connectors from the control board.
4) Remove the old control board and install the new control board (
or Later).
5) Connect the connectors to the new control board.
6) Replace the control box cover in its correct position.
7) Turn on the power supply, then move the control switch to the "ICE" position.
8) "00" appears in the display of the new control board.
9) Press the "SERVICE 1" button to increase the first digit in the display and the
"SERVICE 2" button to increase the second digit. Digits appear in the following order:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F. When a valid model code is displayed, the dot
in the bottom right of the display turns on. For IM-500SAB, set model code to "08".
10) When the desired model code is displayed, press the "RESET" button to save the
setting. "on" appears in the display.
11) Replace the front panel in its correct position.
WARNING
30
P01873-01 Version 1.3A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents