Indicators - BenQ W2000w User Manual

Table of Contents

Advertisement

15. Connect the power and restart the projector.
16. After the startup logo is displayed, reset the lamp timer via the OSD menu.
Under the Advanced OSD menu, go to System Setup : Advanced > Lamp Settings > Reset
Lamp Timer, and select Reset.
Under the Basic OSD menu, if there's no signal connected to the projector, go to Reset Lamp
Timer and select Reset; if there are signals connected, go to Settings > Reset Lamp Timer,
and select Reset.
Do not reset if the lamp is not new or replaced as this could cause damage.
A "Reset Successfully" message is displayed to notify that the lamp time has been reset to "0".

Indicators

There are three indicators which show the status of the projector. Check the following information
about the indicator lights. If there is anything wrong, turn the projector off and contact your dealer.
Light
Orange
Green
Flashing
Green
Orange
Flashing
Red
Green
Red
Green
Green
Green
Off
Off
Red
Red
Red
Flashing
Red
Green
Green
Red
Flashing
52
Maintenance
Stand-by mode
Off
Off
Powering up
Off
Off
Normal operation
Off
Off
Normal power-down cooling
Off
Off
Downloading
Red
Red
CW start fail
Off
Red
Scaler reset fail
Off
Red
Burn-in ON
Off
Off
Burn-in OFF
Green
Lamp1 error in normal operation
Off
Red
Orange
Lamp is not lit up
Off
Flashing
Fan 1 error (the actual fan speed is ±25% outside the desired
Red
Off
speed)
Fan 2 error (the actual fan speed is ±25% outside the desired
Off
speed)
Fan 3 error (the actual fan speed is ±25% outside the desired
Off
speed)
Fan 4 error (the actual fan speed is ±25% outside the desired
Off
speed)
Status & Description
Power events
Lamp events
Thermal events