4. Phase Modified Operation by External Sync Signal

Even though time code is not recorded on the tape, the D-15 can be locked
onto external sync signals such as WORD IN, VIDEO IN, AES/EBU digital signals
in phase modified operation.
Interconnections
As shown in the schematic, external sync signals are input to either WORD
IN, VIDEO IN or AES/EBU IN which matches the output of external equipment.
External equipment
WORD SYNC signal
IN
75
ON
OFF
CH2
IN
AES/EBU signal
Settings Prior to Phase Modified Operation
Any one of the following setups are made depending on type of external
sync signal that is to be input.
<When using WORD IN>
1
. Set the D-15 front panel [CLOCK] switch to [EXT].
2
. Select "503-001 (WORD)" by the SETUP mode "503-***" (Selecting the external
sync signal).
When the external sync signal is correctly input, [EXT CLOCK] will be lit in
the display.
3
. Set FS to the same FS of the external sync signal which is input.
Set to [44.1kHz] or [48kHz] with the D-15 front panel [SAMPLING FREQ]
switch.
Model 8335 (TC/SYNC card) Owner's Manual