Fujitsu AUXG12KVLA Design & Technical Manual page 339

3-unit multi-split type
Hide thumbs Also See for AUXG12KVLA:
Table of Contents

Advertisement

 Floor type
Model: AGYG09KVCA
Outdoor temperature
(°CDB)
-15.0
-10.0
-5.0
0.0
5.0
7.0
10.0
15.0
20.0
24.0
Model: AGYG12KVCA
Outdoor temperature
(°CDB)
-15.0
-10.0
-5.0
0.0
5.0
7.0
10.0
15.0
20.0
24.0
Model: AGYG14KVCA
Outdoor temperature
(°CDB)
-15.0
-10.0
-5.0
0.0
5.0
7.0
10.0
15.0
20.0
24.0
NOTES:
• TC: Total Capacity (kW)
• Values mentioned in the table are based on the following conditions:
– Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
6-3. Heating capacity
16.0
(°CWB)
TC
-16.0
2.87
-11.0
3.25
-7.0
3.48
-2.0
3.78
3.0
3.78
6.0
3.78
8.0
3.78
10.0
3.78
15.0
3.78
18.0
3.78
16.0
(°CWB)
TC
-16.0
3.83
-11.0
4.33
-7.0
4.64
-2.0
5.04
3.0
5.04
6.0
5.04
8.0
5.04
10.0
5.04
15.0
5.04
18.0
5.04
16.0
(°CWB)
TC
-16.0
4.25
-11.0
4.81
-7.0
5.15
-2.0
5.60
3.0
5.60
6.0
5.60
8.0
5.60
10.0
5.60
15.0
5.60
18.0
5.60
Indoor temperature (°CDB)
18.0
20.0
TC
TC
2.80
2.74
3.17
3.10
3.39
3.31
3.69
3.60
3.69
3.60
3.69
3.60
3.69
3.60
3.69
3.60
3.69
3.60
3.69
3.60
Indoor temperature (°CDB)
18.0
20.0
TC
TC
3.74
3.65
4.23
4.13
4.53
4.42
4.92
4.80
4.92
4.80
4.92
4.80
4.92
4.80
4.92
4.80
4.92
4.80
4.92
4.80
Indoor temperature (°CDB)
18.0
20.0
TC
TC
4.15
4.05
4.70
4.58
5.03
4.90
5.46
5.33
5.46
5.33
5.46
5.33
5.46
5.33
5.46
5.33
5.46
5.33
5.46
5.33
- 331 -
22.0
24.0
TC
TC
2.67
2.60
3.02
2.94
3.23
3.15
3.51
3.42
3.51
3.42
3.51
3.42
3.51
3.42
3.51
3.42
3.51
3.42
3.51
3.42
22.0
24.0
TC
TC
3.56
3.47
4.02
3.92
4.31
4.20
4.68
4.56
4.68
4.56
4.68
4.56
4.68
4.56
4.68
4.56
4.68
4.56
4.68
4.56
22.0
24.0
TC
TC
3.95
3.85
4.47
4.35
4.78
4.66
5.20
5.06
5.20
5.06
5.20
5.06
5.20
5.06
5.20
5.06
5.20
5.06
5.20
5.06
6. Capacity table