Fujitsu AUXG12KVLA Design & Technical Manual page 19

3-unit multi-split type
Hide thumbs Also See for AUXG12KVLA:
Table of Contents

Advertisement

Model name
Power supply
Available voltage range
Capacity
Input power
Running current
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Recommended static pressure
Cooling
Sound pressure level *
Heating
Cooling
Sound power level
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Liquid
Size
Connection
Gas
pipe
Method
Material
Drain hose
Tip diameter
Cooling
Operation range
Heating
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 25 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-3. Slim duct type
kW class
W
A
HIGH
MED
LOW
QUIET
3
m
/h
HIGH
MED
LOW
QUIET
W
Pa
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
dB (A)
mm
mm
mm
kg
mm (in)
mm
°C
%RH
°C
ARXG18KLLAP
1Ø 230 V ~50 Hz
198—264 V
5.0
73
0.44
940
880
820
750
940
880
820
750
Sirocco fan × 3
81
0 to 90
32
30
29
27
32
30
29
27
58
58
294 × 700 × 39.9
1.3
3 × 14
Copper tube
Aluminum
Steel sheet
198 × 900 × 620
276 × 1,168 × 772
20
26
Ø6.35 (Ø1/4)
Ø12.70 (Ø1/2)
Flare
PVC
Ø25 (I.D.), Ø32 (O.D.)
18 to 32
80 or less
16 to 30
- 11 -
2. Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents