Model name
Power supply
Available voltage range
Capacity
HIGH
MED
Input power
Fan
LOW
QUIET
Running current
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Recommended static pressure
Cooling
Sound pressure level *
Heating
Cooling
Sound power level
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Size
Connection pipe
Method
Material
Drain hose
Tip diameter
Cooling
Operation range
Heating
NOTES:
• Values mentioned in the table are based on the following conditions:
– Static pressure: 15 Pa
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-2. Mini duct type
kW class
W
A
HIGH
MED
LOW
QUIET
3
m
/h
HIGH
MED
LOW
QUIET
W
Pa
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
dB (A)
mm
mm
kg
Liquid
mm (in)
Gas
mm
°C
%RH
°C
ARXG18KSLAP
1Ø 230 V ~ 50 Hz
198—264 V
5.0
63
38
22
19
0.49
940
750
540
480
940
750
540
480
Sirocco fan × 3
80
0 to 50
33
29
26
23
33
29
26
23
58
59
336 × 690 × 26.6
1.30
2 × 16
Copper tube
Aluminum
Steel sheet
198 × 900 × 450
250 × 1,130 × 580
18.5
23.0
Ø6.35 (Ø1/4)
Ø12.7 (Ø1/2)
Flare
PVC
Ø25 (I.D.), Ø32 (O.D.)
18 to 32
80 or less
16 to 30