STRAIGHT STITCHING (1)

SET THE PATTERN SELECTOR DIAL AT "
AT THE CENTER OF NEEDLE PLATE HOLE.
ADJUSTMENT PROCEDURE:
1. REMOVE THE FACE COVER (SEE PAGE 6).
2. SET THE PATTERN SELECTOR DIAL AT "
NEEDLE DROP POSITION.
3. IF THE NEEDLE DROP POSITION IS NOT THE CENTER OF THE NEEDLE PLATE HOLE, REMOVE
THE FACE COVER AND LOOSEN THE SETSCREW (C) AND ADJUST THE NEEDLE DROP POSITION
BY TURNING THE ECCENTRIC PIN.
NOTE: WHEN ADJUSTING THE NEEDLE DROP POSITION, MAKE SURE THE ECCENTRIC PIN SHOULD
SIT WITH ITS HEAD OFF-CENTERED DOWNWARD.
4. AFTER THE ADJUSTMENT OF NEEDLE DROP POSITION, TIGHTEN SETSCREW (C) AND ATTACH
THE FACE COVER.
SETSCREW 3 X 4 (C)
A D J U S T T H E N E E D L E
D R O P P O S I T I O N B Y
TURNING THE ECCENTRIC
PIN AS SHOWN.
www.promelectroavtomat.ru
MECHANICAL ADJUSTMENT
", THE STANDARD NEEDLE DROP POSITION SHOULD BE
" AND ZIGZAG WIDTH DIAL AT " 0 ", THEN CHECK THE
ECCENTRIC PIN (D)
ECCENTRIC PIN
POSITION
12
NEEDLE PLATE HOLE
A = B