[Setting procedure of Level 1]
4
3
Setting No.
3
6
Set value
109
™Turn OFF the power switch
and turn ON the power switch
after approximately one
second.
™Change of the set value is
determined by turning OFF
the power switch.
1) P r e s s s w i t c h 1 f o r
a p p r o x i m a t e l y t h r e e
seconds.
1
2) Press switch 4.
3) This screen is the function
setting screen.
Change the setting No. with
"+/–" Key of switch 3.
For the details of setting
No., refer to 9. FUNCTION
SETTING LIST.
Example) Changing the
number of
rotation of
reverse feed
stitching
(Setting No. 8)
Change the setting No. to "8"
with "+" Key of switch 3 in the
figure above.
™ Press switch 6.