Table 8 Electrical Specifications W**La - Bard W60LB-A Installation Instructions Manual

Wall mounted packaged air conditioner
Table of Contents

Advertisement

Electrical Specifications – W**LA Series
No.
Rated
Field
MODEL
Volts &
Power
Phase
Circuits
W18LA-A00,A0Z
1
A05
1
230/208-1
A08
1
A10
1
W24LA-A00, A0Z
1
A05
1
230/208-1
A08
1
A10
1
W24LA-B00, B0Z
1
230/208-3
B06
1
W24LA-C00, C0Z
1
460-3
C06
1
W30LA-A00, A0Z
1
A05
1
A08
230/208-1
1
A10
1
A15
1 or 2
W30LA-B00, B0Z
1
B09
230/208-3
1
B15
1
W30LA-C00, C0Z
1
C09
460-3
1
C15
1
W36LA-A00, A0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
W36LA-B00, B0Z
1
B09
230/208-3
1
B15
1
W36LA-C00, C0Z
1
C09
460-3
1
C15
1
W42LA-A00, A0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
W42LA-B00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W42LA-C00, C0Z
1
C09
460-3
1
C15
1
W48LA-A00, A0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
W48LA-B00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W48LA-C00, C0Z
1
C09
460-3
1
C15
1
W60LB-A00, A0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
W60LB-B00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W60LB-C00, C0Z
1
C09
460-3
1
C15
1
W72LB-A00, A0Z
1
A05
1
230/208-1
A10
1 or 2
A15
1 or 2
W72LB-B00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W72LB-C00, C0Z
1
C09
460-3
1
C15
1
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor
sizing.
CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to Note 8 of Table 310 regarding Ampacity
Adjustment Factors when more than three current carrying conductors are in a raceway.
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National
Electrical Code and all local codes.
TABLE 8
Single Circuit
Maximum
Minimum
Field
External
Circuit
Power
Fuse or Ckt.
Ampacity
Wire Size
Brkr.
16
20
12
30
30
10
46
50
8
56
60
6
21
30
10
30
30
10
46
50
8
56
60
6
15
20
12
22
25
10
9
15
14
11
15
14
26
35
8
32
35
8
47
50
8
58
60
6
84
90
4
19
20
12
33
35
8
51
60
6
9
15
14
17
20
12
26
30
10
29
35
8
32
35
8
58
60
6
84
90
4
23
30
10
33
35
8
51
60
6
11
15
14
17
20
12
26
30
10
32
50
8
32
50
8
58
60
6
84
90
4
25
35
8
25
35
8
33
35
8
51
60
6
12
15
14
17
20
12
26
30
10
34
50
8
34
50
8
58
60
6
84
90
4
26
35
8
26
35
8
33
35
8
51
60
6
12
15
14
17
20
12
26
30
10
41
60
8
41
60
8
59
60
6
85
90
3
28
40
8
28
40
8
34
40
8
52
60
6
14
20
12
18
20
12
27
30
10
58
60
6
58
60
6
62
70
6
88
90
3
40
60
8
40
60
8
40
60
8
55
60
6
18
25
10
18
25
10
27
30
10
 Minimum
 Maximum
Circuit
External Fuse or
Ground
Ampacity
Ckt. Breaker
Wire
Ckt. A
Ckt. B
Ckt. A
12
10
10
10
10
10
10
10
12
10
14
14
10
10
10
10
8
58
26
60
12
10
10
14
12
10
10
10
10
8
58
26
60
10
10
10
14
12
10
10
10
10
8
58
26
60
10
10
10
10
14
12
10
10
10
10
8
58
26
60
10
10
10
10
14
12
10
10
10
10
8
60
26
60
10
10
10
10
12
12
10
10
10
8
58
26
60
8
58
52
60
10
10
10
10
10
10
10
Dual Circuit
Field Power
Ground
Wire Size
Wire Size
Ckt. B
Ckt. A
Ckt. B
Ckt. A
30
6
10
10
30
6
10
10
30
6
10
10
30
6
10
10
30
6
10
10
30
6
10
10
60
6
6
10
Manual
2100-640I
Page
27 of 32