Wall Mount General Information; Air Conditioner Wall Mount Model Nomenclature; Shipping Damage; General - Bard W60LB-A Installation Instructions Manual

Wall mounted packaged air conditioner
Table of Contents

Advertisement

WALL MOUNT GENERAL INFORMATION

AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE

W
42
MODEL SERIES
CAPACITY
18 – 1½ Ton
42 – 3½ Ton
24 – 2 Ton
48 – 4 Ton
30 – 2½ Ton
60 – 5 Ton
36 – 3 Ton
72 – 6 Ton
A – Right Hand
L – Left Hand
SPECIALTY PRODUCTS 
A – 230/208/60/1
B – 230/208/60/3
C – 460/60/3
D – 240/220/50/1
 Insert "D" for dehumidification with hot gas reheat.
Reference Form 7960-736 for complete details.
NOTE: Vent options X, B and M are without exhaust capability. May require separate field-supplied barometric relief in building.

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be
checked for external signs of shipping damage. If
damage is found, the receiving party must contact
the last carrier immediately, preferably in writing,
requesting inspection by the carrier's agent.

GENERAL

The equipment covered in this manual is to be installed
by trained, experienced service and installation
technicians.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.
The refrigerant system is completely assembled and
charged. All internal wiring is complete.
The unit is designed for use with or without duct work.
Flanges are provided for attaching the supply and
return ducts.
Manual 2100-640I
Page
4 of 32
A
A
A
REVISION
(Non-Standard)
VOLTS & PHASE
E – 240/220/50/3
or 220/200/50/3
F – 415/380/50/3
X – Barometric Fresh Air Damper (Standard)
B – Blank-off Plate
M – Motorized Fresh Air Damper
C – Commercial Ventilator - No Hood with Exhaust
10
X
X
X
KW
FILTER OPTIONS
X – 1" Throwaway (Standard)
W – 1" Washable
P – 2" Pleated
VENTILATION OPTIONS
V – Commercial Ventilator - Full Flow with Hood
R – Energy Recovery Ventilator - Motorized with Exhaust
Y – Full Flow Economizer - DB Temp.
Z – Full Flow Economizer - Enthalpy
These instructions explain the recommended method
to install the air cooled self-contained unit and the
electrical wiring connections to the unit.
These instructions and any instructions packaged with
any separate equipment required to make up the entire
air conditioning system should be carefully read before
beginning the installation. Note particularly "Starting
Procedure" and any tags and/or labels attached to the
equipment.
While these instructions are intended as a general
recommended guide, they do not supersede any
national and/or local codes in any way. Authorities
having jurisdiction should be consulted before the
installation is made. See page 3 for information on
codes and standards.
Size of unit for a proposed installation should be based
on heat loss calculation made according to methods of
Air Conditioning Contractors of America (ACCA). The
air duct should be installed in accordance with the
Standards of the National Fire Protection Association
for the Installation of Air Conditioning and Ventilating
Systems of Other Than Residence Type, NFPA No.
90A, and Residence Type Warm Air Heating and Air
Conditioning Systems, NFPA No. 90B. Where local
regulations are at a variance with instructions, installer
should adhere to local codes.
X
X
A
CONTROL MODULES
(See Spec. Sheet S3502)
COIL OPTIONS
X – Standard
1 – Phenolic Coated Evaporator
2 – Phenolic Coated Condenser
3 – Phenolic Coated Evaporator
and Condenser
OUTLET OPTIONS
X – Front (Standard)
T – Top Outlet (W30A, W36A only)
COLOR OPTIONS
X – Beige (Standard)
8 – Dark Bronze
1 – White
A – Aluminum
4 – Buckeye Gray
S – Stainless Steel
5 – Desert Brown

Advertisement

Table of Contents
loading

Table of Contents