OBSERVED PROBLEM
Fireplace produces a clicking/ticking noise just
after burner is lit or shut off
Fireplace produces unwanted odors
Gas odor even when gas control valve is off
Gas odor during combustion
Dark residue on logs or inside of fireplace
22
TROUBLESHOOTING Continued
POSSIBLE CAUSE
1. Metal expanding while heating or contracting
while cooling
1. Fireplace burning vapors from paint, hair
spray, glues, etc. (See IMPORTANT state-
ment above)
2. For propane/LP gas, low fuel supply
3. Gas leak. See Warning statement at top of
Page
1. Gas leak. See Warning statement at top of
Page
2. Control valve defective
1. Foreign matter between control valve and
burner
2. Gas leak. See Warning statement at top of
Page
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
4. Improper venting or excessive blockage
5. Excessive amounts of embers and pan mate-
rial
SuperiorFireplaces.us.com
REMEDY
1. This is normal with most fireplaces.
If noise is excessive, contact qualified
service person
1. Ventilate room. Stop using odor caus-
ing products while fireplace is running
2. Contact local propane/LP supplier
3. Locate and correct all leaks (see Gas
Line Hook-Up, Page 11)
1. Locate and correct all leaks (see Gas
Line Hook-Up, Page 11)
2. Replace control valve
1. Take apart gas tubing and remove
foreign matter
2. Locate and correct all leaks (see Gas
Line Hook-Up, Page 11)
1. Properly locate logs (see log placement
sections on Pages 13 and 14)
2. Clean out air holes at burner inlets.
Periodically repeat as needed
3. Remove blockage or replace burner
4. Have vent system inspected, including
termination cap. Remove any restric-
tions or obstruction
5. Clear excess embers until a minimum
gap of 1/2" remains under grate