Break‐In Fires 
 
This wood burning unit is constructed of heavy gauge 
steel and cast iron and is built to last a long time. 
However, in order to ensure no excessive thermal stresses are induced on the metal during the 
first fire, three break‐in fires should be burned, each one slightly hotter than the last. These 
break‐in fires will not only help the stove body acclimate to the high temperatures of the fire, 
but will also slowly cure the high temperature stove paint, which will ensure the high 
quality finish lasts for years. 
 
This stove has a single air control rod which regulates the wood burn rate; when the primary air 
control slide is pulled all the way out of the unit, the stove will burn more slowly and put out 
heat over a longer time period.  Conversely, when the air control slide is pushed all the way in, 
the unit will burn more quickly and put out a larger amount of heat over a relatively shorter time 
period.  Do not attempt to modify the range of air control adjustment for any reason. 
 
The first break‐in fire should be just a large kindling fire, getting the stove to about 300°F. Once 
this temperature has been reached, allow the fire to die out with the air control open. The 
second and third break‐in fires should be a bit larger, with some small dry splits added to the 
kindling load.  The temperature goal during these fires is about 350°F – 450°F; don't let the fire 
get hotter than that. 
 
Continuous Operation 
 
After the break‐in fires are complete, this unit is ready for continuous operation.  When burning 
the stove continuously, do not allow ash and coals to accumulate higher than the air hole in the 
dog box.  Excessive coaling is often a result of burning wood at too high a burn rate, and the coal 
bed should be allowed to burn down before reloading the stove with fresh wood. 
 
Combustion air is delivered to the stove at two locations: The majority of the primary combustion 
air enters the firebox via the air‐wash system which keeps the glass clean and feeds the primary 
combustion flames on the top surfaces of the wood; some primary combustion air is feed into the 
coal bed via the dog box hole in the bottom, front box of the stove.  (This air is supplied from 
under the unit.) Every effort must be taken to maintain the area in front of this hole free of ash. 
 
When loading the stove for a long term burn, it is most useful to rake a "v" in the center of the 
coal bed, to allow the primary air bleed hole to push air all the way to the rear of the unit. 
 
After loading the stove with a full firebox of fresh wood, it is important to operate the unit with 
the air control in the full open position to properly char the wood load and drive off the initial 
moisture in the fresh wood.  Once the wood has been properly charred and is completely 
ignited, the air control can then be set to the desired heat output level. 
 
This unit also offers a new feature.  When loading the stove for a long low burn, you can set the 
air control damper to allow the unit to heat up and get a good burn going before the air is closed 
off to the low position.  Simply pull the rod out to low and turn it counter‐clockwise until 
you hear a slight "click" (about a quarter of a turn).   When it is ready the damper will shut itself. 
This will work for low and medium low settings. 
18
OPERATION 
First Fire‐ Remember to open a door 
and/or window to ventilate the area. 
You may find it necessary to open 
several doors or windows for plenty of 
ventilation. 