Specifications

Electrical
Loop Limit
2 kΩ maximum at
48 VDC (nominal 20 mA
minimum loop current)
300 Ω typical
DC Resistance
(Talk Mode)
Monitor
Impedance
TS22
5 kΩ nominal at 1 kHz
TS22A
120 kΩ nominal at 1 kHz
Rotary Dial Output
Pulsing Rate
10 pps ±5 pps
Percent Break 61 % ± 2 %
Interdigit
1000 ms typical
Interval
Leakage
>50 kΩ
During Break
DTMF Output
Tone
±1% maximum
Frequency
Error
Tone Level
-3 dBm combined (typical)
High versus
4 dB maximum
Low Tone
Difference
Monitor Amplifier
9 V battery; provides 25 hours
Power Source
continuous use, typical
Speaker Levels for
Low, medium, high and off
TS22
Automatic Power
After 5 min. of no audio signal
Shut Off
Speakerphone
Low, medium, high and off
Levels TS22A
Power Source
Shared line and battery power
Physical
Measurement
10.25 in x 2.69 in x 3.38 in
(26 cm x 6.83 cm x 8.57 cm)
Weight
TS22
21 ounces (.595 kg)
TS22A
22 ounces (.624 kg) typical
Environmental
Temperature
Operating:
29 °F to 140 °F (-34 °C to 60 °C)
Storage
-40 °F to 150 °F (-40°C to 66 °C)
Altitude
To 10,000 feet (3,000 meters)
Relative Humidity
5 % to 95 %
Certifications and Compliance
Conformité Européenne. Conforms to
relevant European Union directives.
Specifications subject to change without notice.