Burner and nozzle characteristics tables
1 Natural Gas G20 – 20 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
2
Natural Gas G20 – 25 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
3
Natural gas G25/G25.3 - 25 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
4
Natural gas G25.1 – 25 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
5 Natural Gas G25 – 20 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
6 Natural gas G2.350 – 13 mbar
Rated heating capacity (kW)
Nozzle diameter (1/100 mm)
Reduced flow rate (W)
Primary air (mm)
Installation
AUX
1.1
76
400
1
AUX
1.1
73
400
1
AUX
1.1
76
400
1
AUX
1.1
76
400
1
AUX
1.1
82
400
1
AUX
1.1
100
400
1
R
UR
3.1
3.3
126
130
900
1600
1
0,5
R
UR
3.1
3.3
120
123
900
1600
1
1
R
UR
3.0
3.3
126
135
900
1600
1
0,5
R
UR
3.1
3.3
135
140
900
1600
1
1
R
UR
3.1
3.3
140
145
900
1600
1
0.5
R
UR
3.1
3.3
175
180
900
1600
1
2
UR*
6.0
175
1800
1
UR*
6.0
165
1800
0.5
UR*
6.0
185
1800
0.5
UR*
6.0
190
1800
0.5
UR*
6.0
200
1800
0.5
UR*
6.0
280
1800
3