Input Status - U-Line U-3045WCINT-60B User Manual & Service Manual

45cm single zone wine cellar
Hide thumbs Also See for U-3045WCINT-60B:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Relay Toggle
Up
Down
Relay toggle is used to manually switch the state of each
relay to test for proper operation. In addition to the AC
relays, DC switches may also be toggled. Relay toggle can
also be used to force the unit into a particular state.
ID
Description
Mull
Mullion Heater (Not Used)
Cond
Fan (Not Used)
Def
Defrost Valve (45cm models)
Pan
Pan heater (Not Used)
Comp
Compressor
F1
Evaporator Fan
F3
Condenser Fan
L1
Zone Lighting
To access Relay Toggle
4. Press
to select "Relay Toggle".
5. Press
.
6. Press
and
to scroll through each relay and DC
output.
7. Press
to toggle.
To exit the Relay Toggle menu press
to Menu" and press
to confirm.
Select
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF
Voltage
AC
AC
AC
AC
AC
DC
DC
DC
to select "Return

Input Status

Up
Down
Input status displays the current state of each available
input.
ID
Description
Door
Door Switch
To access Input Status
1. Press
to select "Input Status".
2. Press
.
3. Press
and
to scroll through available
information.
To exit the Input Status menu press
to Menu" and press
Outputs
Up
Down
Outputs is used to monitor the state of DC outputs.
ID
Description
Evap Fan
Evaporator Fan
Condenser Fan
Condenser Fan
Light
Zone Lighting
69
u-line.com
RETURN TO MENU
INPUT STATUS
DOOR OPEN
IN2 OPEN
State
Open - Closed
to select "Return
to confirm outputs.
RETURN TO MENU
OUTPUTS
EVAP FAN=0%
CONDENSER FAN=0%
Value
0 or 100%
0 or 100%
Off - Low - Med - High
Control Operation - Service 4
Select
Select

Advertisement

Table of Contents
loading

This manual is also suitable for:

3045wc3000 series

Table of Contents