BASIC PROGRAMMING
DETERMINE THE WIRING TYPE
ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED
ENTRAPMENT PROTECTION DEVICE
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring when
Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)
• Timer-to-Close (TTC) feature not available.
MONITORED ENTRAPMENT PROTECTION DEVICE
Photoelectric Sensor
To Program:
1
Press and hold the LEARN and CLOSE buttons until the LED
goes out (approximately 3 seconds).
Electrical Box
Logic Board
D7
D5
U4
D6
D4
014A1030
J4
C32
C20
TP1
R25
C9
U1
C21
L5
^^^^
AUX ANT
AUX ANT
C18
J2
R27
D14
K2
TTC
LEARN
STOP CLOSE OPEN
LT
LED
C29
R24
1
2
3
4
5
6
7
P1
LMEP1
LMEP2
STOP
CLOSE
OPEN
D9
COM
INTRLK
To Reset to B2 with Monitored Entrapment Protection Device:
1
Press and hold the LEARN and STOP buttons until the LED
goes out (approximately 3 seconds).

REMOTE CONTROLS

MODE
OPEN
B2
X
B2 with TTC
X
C2
X
LEARN
STOP CLOSE OPEN
D14
LED
1
2
3
4
5
6
RADIO OPERATION
CLOSE
X
X (3-button remote)
ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT
MONITORED ENTRAPMENT PROTECTION DEVICE
(FACTORY DEFAULT)
• Momentary contact to open and stop with constant pressure to
close.
• Open override that reverses when closing by any opening
device.
• Wiring for entrapment protection device to reverse.
NOTE: The operator will automatically convert to B2 wiring when
Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)
• Timer-to-Close (TTC) feature not available.
NON-MONITORED ENTRAPMENT PROTECTION DEVICE
Reset to FACTORY DEFAULT (C2) when the Monitored
Entrapment Protection Device has been learned and then
removed:
1
Remove any monitored entrapment protection devices.
2
Turn the main power OFF and then ON to restore the operator
to the FACTORY DEFAULT setting.
7
STOP
REVERSE WHILE CLOSING
X
X
X
21
Sensing Edge
X
X
X
TTC RESET
X when open

Hide quick links: