Put the chimney cap into place.
Wash the roof flashing with a solvent or vinegar, then paint it with rust-proof paint.
Table 3

OFFSET CHIMNEY INSTALLATION

After reaching the location requiring the elbow, proceed as follows. The minimum chimney height
when using elbows is:
Fireplace Model
Chimney Model
Vertical installation
Two (2) elbows
Four (4) elbows
Table 4
Figure 31
NOTES:
• Must return to vertical before penetrating ceiling or floor.
• A maximum of 2 offsets are allowed.
AC *
Chimney
Spacer (built
into flashing)
Flashing
Roof Down Slope Hole Size
ASHT * / HT6103+ * / DuraTech DTC *
6"
12-3/8" (314 mm)
12-9/16" (319 mm)
13" (330 mm)
13-7/8" (352 mm)
14-7/8" (378 mm)
16-1/8" (410 mm)
17-1/2" (445 mm)
Minimum Chimney Height Using Elbows
ASHT
/ S2100+
/ HT6103+
*
*
12 feet (3.66 m)
15 feet (4.57 m)
17 feet (5.18 m)
Figure 32
S-2100+ * / HT6000+ *
AC *
6"
6"
14-1/8" (359 mm)
15" (380 mm)
14-3/8" (365 mm)
15-3/8" (390 mm)
14-7/8" (378 mm)
16-1/8" (410 mm)
15-3/4" (400 mm)
16-7/8" (430 mm)
17" (432 mm)
18-1/4" (465 mm)
18-3/8" (467 mm)
19-5/8" (500 mm)
20" (508 mm)
21-3/8" (545 mm)
Ultima™ CF
/ HT6000+
/ AC
/ DuraTech DTC
*
*
*
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
After reaching the location requiring the
elbow, proceed as follows:
ASHT
/ HT6103+
/ S-2100+
*
*
DuraTech DTC
Chimneys
*
1. Install the first elbow; turn it in the required
direction. Fasten it to the chimney with
the three (3) 1/2" (12 mm) metal screws
provided with the elbow.
2. Install the necessary chimney lengths to
achieve the required offset. Lock the chimney
lengths together: it is recommended to use
three (3) 1/2" (12 mm) screws. If the offset
length is made of two (2) chimney lengths or
more, use an offset or roof support halfway
up the offset. If penetrating a wall, install
a wall radiation shield (see Figures 34 and
36).
3. Use another elbow to turn the chimney verti-
cally. Secure the elbow, using three (3) 1/2"
(12 mm) screws (provided with the elbow).
4. Use a plumb-bob to line up the center of
the hole. Cut a hole for the chimney in the
ceiling/floor. Frame this hole as described
previously (refer to section Chimney Instal-
lation Instructions).
5. From below, install a firestop (See Figure
29a).
6. A support (ST
or SO+
*
the first 15' section (5 m).
7. Continue with the regular installation.
AC Chimney
*
1. Install the first elbow. Turn it in the required
direction. To lock it in place, turn 1/8 of a
turn. Fasten the straps attached to the elbow
to the surrounding frame, using nails or
drywall screws (Figure 34).
2. Install the necessary chimney lengths to
achieve the required offset. Lock the chimney
lengths together. If penetrating a wall, use
a wall radiation shield.
3. Use another elbow to turn the chimney
vertically. Lock it to the chimney. Fasten
the straps attached to the elbow to the
*
surrounding framing using nails or drywall
screws.
4. Use a plumb-bob to line up the center of the
hole. Cut a hole for the chimney in the ceiling.
Frame this hole as described previously.
5. From below, install a firestop (see Figure
29c).
6. Continue with the regular installation.
NOTE: When using AC chimney, an AC6SB
starter section must be used before installing
an elbow. When an offset is needed imme-
diately off the top of the fireplace, an elbow
starter section, AC6SB30
Available from Security Chimneys
*
Available from DuraVent
**
/ HT6000+
/
*
*
) must be used on
*
*
, is available.
*