Ricoh Aficio MP171 Field Service Manual page 29

Hide thumbs Also See for Aficio MP171:
Table of Contents

Advertisement

Value
Proxy error (Illegal user name or
5
password)
8
Other error
Request number confirmation
9
executing
20
Dial-up authentication error
21
Answer tone detection error
22
Carrier detection error
23
Invalid setting value (modem)
24
Low power supply current
25
unplugged modem
26
Busy line
8.
Exit the SP mode.
SP5816-208 Error Codes
Cause
Operation Error,
Incorrect Setting
Meaning
Code
Meaning
Attempted registration without
-1200
execution of a confirmation and
3
no previous registration.
-1200
Attempted setting with illegal
4
entries for certification and ID2.
-1200
A confirmation request was made
6
after the confirmation had been
already completed.
-1200
Update certification failed
8
because mainframe was in use.
Settings for @Remote Service
Solution/ Workaround
Check Proxy user name and password.
See "SP5816-208 Error Codes" below this.
Processing... Please wait.
These errors occur only in the modems that
support @Remote.
Solution/ Workaround
Perform Confirmation before
attempting the Registration.
Check ID2 of the mainframe.
Execute registration.
Check the mainframe
condition. If the mainframe is
in use, try again later.
27

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents