Main SP Tables-2

SP2-XXX (Drum)

2001
[C biasControl]
2-001-001
C setting
2-001-002
C(low) setting
2-001-011
Vd_ref_lowhumi
2-001-012
Vd_ref_midhumi
2-001-013
Vd_ref_highhumi
[-1350 to -900 / -1020 / 1V/step]
C: bias value.
E
• This setting is available when the bias
control is Off.
[-400 to -200 / -350 / 50V/step]
E
C(low): The value of C(low) output.
[-700 to -400 / -420 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, low humidity.
E
• This setting is available when the bias
control is On.
[-700 to -400 / -470 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, mid humidity.
E
• This setting is available when the bias
control is On.
[-700 to -400 / -490 / 10V/step]
Displays and adjusts the target dark potential
(Vd) in the Env Division, high humidity.
E
• This setting is available when the bias
control is On.