Hoshizaki SRK-8H Instruction Manual page 22

Modular crescent cuber
Hide thumbs Also See for SRK-8H:
Table of Contents

Advertisement

1. Icemaker
Icemaker Water
Minimum Icemaker
Supply Inlet
Water Supply Line Size
1/2" Female Pipe
1/4" Nominal ID
Thread (FPT)
Copper Water Tubing or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Icemaker Drain
Outlet 3/4" FPT
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker
Ice
Storage
Bin
Bin Drain Outlet
3/4" FPT
Minimum 3/4" Nominal ID Hard Pipe
KMS-830MLH
Fig. 12
Icemaker Drain
Minimum Icemaker
Outlet
Drain Line Size
3/4" Female Pipe
3/4" Nominal
Thread (FPT)
ID Hard Pipe or
Equivalent
Vent Tube
Icemaker Condensation
Drain Outlet
3/8" OD Hard Tube
Icemaker Water Supply
Line Shut-Off Valve
Icemaker Water Supply
Line Drain Valve
Vent Tube
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the drain.
22
Minimum 1/4" Nominal ID
Copper Water Tubing
2-inch
(5-cm)
air gap
Floor
Drain

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kms830mlhSrk-8h3