Massachusetts Requirements - Superior Fireplaces DRC6300 Series Installation And Operation Instruction Manual

Hide thumbs Also See for DRC6300 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
These electronic appliances are remotely
controlled and feature an electronic intermit-
tent pilot ignition system or standing pilot.
External electrical power is required to operate
these units.
These electronic models come standard with a
remotely-modulated gas valve; flame appear-
ance and heat output cannot be controlled at
the gas valve. The BTU Input for these appli-
ances is shown in Table 1.
Input (BTU/HR)
Model
Natural Gas
40 in.
32,000 to 50,000
45 in.
40,000 to 57,000
Propane Gas
40 in.
32,000 to 50,000
45 in.
43,000 to 56,000
Table 1
Gas Pressure—All Models
Appliance inlet and manifold gas pressure
requirements are listed in Tables 2 and 3.
Inlet Gas Supply Pressure
Fuel #
Minimum
5.5" WC
Natural
(1.37 kPa)
Gas
11.0" WC
Propane
(2.74 kPa)
Table 2
Manifold Gas Supply Pressure
Fuel #
Low
Natural
1.6" WC
Gas
(.4 kPa)
6.3" WC
Propane
(1.57 kPa)
Table 3
Test gauge connections are provided on the
front of the gas control valve (identified IN for
the inlet and OUT for the manifold side).
Propane tanks are at pressures that will cause
damage to valve components. Verify that the
tanks have step-down regulators to reduce the
pressure to safe levels.
The appliance and its appliance main gas
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its equipment
shutoff valve during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
6
Orifice Sizes—Sea Level To High Altitude
(All Models)
These appliances are tested and approved
for installation at elevations of 0–4500 feet
(0–1372 meters) above sea level, using the
standard burner orifice sizes (marked with an
asterisk (*) in Table 4). For elevations above
4500 feet, contact your gas supplier or qualified
service technician.
Deration—At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either:
Input (BTU/Hr)
• using gas that has been derated by the gas
company; or
• changing the burner orifice to a smaller size
as regulated by the local authorities having
jurisdiction and by the (USA) National Fuel
Gas Code NFPA 54/ANSI Z223.1—latest
edition or, in Canada, the CAN/CGA-B149.1
codes—latest edition.
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1—latest edition or , in Canada,
the CAN/CGA-B149.1- latest edition.
NOTE: Flame appearance will diminish 4% per
thousand feet of altitude.
Maximum
10.5" WC
(2.61 kPa)
Model
13.0" WC
(3.23 kPa)
40" CD
High
3.5" WC
45" CD
(.87 kPa)
10.0" WC
Table 4
(2.49 kPa)
Gas Valve Diagram
The SIT Proflame gas valve is shown in Figure 1.
(From DFC Wire
Main Gas Inlet
Figure 1—SIT Proflame Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Burner Orifice Sizes
Elevation 0–4500 ft ( 0–1372 m)
Nat.Gas
Propane
drill size (inches)
drill size (inches)
0.1405" (#28)*
0.082" (#45)*
40"
• H2286
• J8002
0.150" (#25)*
0.086" (#44)*
45"
• J8001
• H2287
0.1405" (#28)*
0.073" (#49)*
• H2286
• H8807
0.150" (#25)*
0.073" (#49)*
• J8001
• H8807
* Standard size installed at factory
• Part /Cat. Number
Green Wire
(From DFC Wire
Harness)
Manifold (Out)
Test Port
Inlet (In) Test Port
Wire
Harness)
3/8" NPT
General Information
900343-01 01/2018
In Canada - CAN/CGA-2.17-M91 (R2009)
(high altitude):
THE CONVERSION SHALL BE CARRIED
OUT BY A MANUFACTURER'S AUTHO-
RIZED REPRESENTATIVE, IN ACCOR-
DANCE WITH THE REQUIREMENTS OF
THE MANUFACTURER, PROVINCIAL OR
TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.
COMMONWEALTH OF MASSACHUSETTS
REQUIREMENTS
These appliances are approved for installation in
the US state of Massachusetts if the following
additional requirements are met:
• Install this appliance in accordance with
Massachusetts Rules and Regulations 248
C.M.R. Sections 4.00 through 8.00.
• Installation and repair must be done by a
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
• The flexible gas line connector used shall
not exceed 36 inches (92 centimeters) in
length.
• The individual manual shut-off must be a
T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, hori-
zontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
• A hard wired carbon monoxide detector
with an alarm and battery back-up must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified.
Connect GTMS
Wire Harness
Pressure
Regulator
Tower
Yellow Ground Wire
(From DFC Wire
Harness)