Table Of Contents; Packaging; Introduction - Superior Fireplaces DRC6300 Series Installation And Operation Instruction Manual

Hide thumbs Also See for DRC6300 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT/DRC6300 Series Direct-Vent Gas Fireplaces

TABLE OF CONTENTS

Packaging . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . 4
General Information . . . . . . . . . . . . . . . . . . 5
Massachusetts Requirements . . . . . . . . . . 6
Cold Climate Insulation . . . . . . . . . . . . . . . 7
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Vent Termination Clearances . . . . . . . . . . . 8
Detailed Installation Steps . . . . . . . . . . . . . 11
Typical Installation Sequence . . . . . . . . . . 11
Step 1. Framing . . . . . . . . . . . . . . . . . . . . 11
Step 2. Routing Gas Line . . . . . . . . . . . . . 13
Proper Sizing of Gas Line . . . . . . . . . . . . . . 13
Vertical Termination Systems . . . . . . . . . . . 15
Vent Section Length Chart . . . . . . . . . . . . . 15
Horizontal Termination System . . . . . . . . . 19
Step 4. Field Wiring . . . . . . . . . . . . . . . . . 23
Frame Assembly . . . . . . . . . . . . . . . . . . 25
Step 6. Connecting Gas Line . . . . . . . . . . 25
Step 9. Installing Glass Door . . . . . . . . . . 28
Step 10. Burner Adjustments . . . . . . . . . . . 28
Finishing Requirements . . . . . . . . . . . . . . . 30
Operation Warnings . . . . . . . . . . . . . . . . 31
Installation Accessories . . . . . . . . . . . . . . . 32
Gas Conversion Kits . . . . . . . . . . . . . . . . . . 33
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 40
Installation . . . . . . . . . . . . . . . . . . . . . . . 41
Placement . . . . . . . . . . . . . . . . . . . . . . . 42
Burner Adjustments . . . . . . . . . . . . . . . . . . 44
Flame Appearance and Sooting . . . . . . . . . 44
Burner Air Shutter Adjustment . . . . . . . . . . 45
Electronic Appliance Checkout . . . . . . . . . 45
Ordering Replacement Parts . . . . . . . . . . . . 46
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Accessory Components . . . . . . . . . . . . . . . 47
Lighting Instructions . . . . . . . . . . . . . . . . . 49
Maintenance Schedule . . . . . . . . . . . . . . . . 51
Troubleshooting Guide . . . . . . . . . . . . . . . . 52
Replacement Parts List . . . . . . . . . . . . . . . 53
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4
Please read and understand these
instructions before beginning your
installation.

PACKAGING

The assembled fireplace is packaged with the
following:
• Literature Kit (plastic bag shipped in-
side firebox), containing Installation and
Operation Manual (this manual), Safety
Flyer, Glass and Barrier Flyer and Safety-in-
Operation Warning Labels.
• One (1) bag Glowing Embers (Traditional)
• One (1) bag Platinum Embers (Traditional)
• One (1) bag Volcanic Stone (Traditional)
• Remote Control and Wall Receiver
Switch Kit
• Door Modesty Shield
• Log Grate (Traditional)
NOTE: For use with fireplace as shipped from fac-
tory only. Not for use with Contemporary Burner/
Floor Kit.
REQUIRED ACCESSORIES
One of the following Firebox Liner Kits:
a. Ceramic Firebox Liner Kit-
Buff Rustic
b. Ceramic Firebox Liner Kit-
Red Rustic
c. Porcelain Firebox Liner Kit-
Black
d. Ceramic Firebox Liner Kit-
Red Herringbone
e. Ceramic Firebox Liner Kit-
Buff Herringbone
NOTE: Porcelain kits include side and back panels.
Optional for use with log sets. Required when using
the contemporary burner/floor kit.
NOTE:
• IF THE BARRIER BECOMES DAMAGED,
THE BARRIER SHALL BE REPLACED WITH
THE MANUFACTURER'S BARRIER FOR THIS
APPLIANCE.
• FOR USE WITH BARRIER(S) PART NO(S).
J7422 (40" MODELS) AND J7423 (45"
MODELS).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
General Information
900343-01 01/2018

INTRODUCTION

The DRT/DRC6300 Series direct-vent, sealed-
combustion gas fireplaces operate on natural
or propane gas. These appliances feature a
remotely controlled electronic intermittent pilot
ignition system (manual adjustment of the gas
valve settings is not possible).
The DRT/DRC6300 Series is a decorative fire-
place and may not be installed and operated as
the primary heat source in a dwelling.
Electrical power (120 VAC line voltage) is rec-
ommended to operate the fireplace; however,
four (4) "AA" batteries can be used for full-time
operation or as a backup in case of a power
outage.
Approved Vent Components
These fireplaces are designed, tested, and
listed for operation and installation with Secure
Vent
direct vent system components (8" inner,
®
11" outer) manufactured by Innovative Hearth
Products.
These approved vent system components
are labeled for identification. USE ONLY AP-
PROVED VENT COMPONENTS. Do NOT use
any other manufacturer's vent components
with these appliances.
Codes and Standards
These appliances comply with National Safety
Standards and are tested and listed by PFS
Corporation (Report No. F14-106) to Z21.50 (in
Canada, CSA-2.22), and CAN/CGA-2.17-M91 in
both USA and Canada, as vented gas fireplaces.
These appliances are listed by PFS Corpora-
tion for installation in bedrooms and mobile
homes.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (in Canada, the current
CAN/CGA-B149.1 installation code).
The appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 (latest
edition) or the Canadian Electrical Code, CSA
C22.1 (latest edition).

Advertisement