The appliance can work in the following
modes:
• 220-240 V 2~
3 x 10 mm² three-core cable.
• 3220-240 V 3~
4 x 6 mm² four-core cable.
• 220-240 V 1N~
3 x 10 mm² three-core cable.
• 380-415 V 2N~
4 x 6 mm² four-core cable.
• 380-415 V 3N~
5 x 2.5 mm² five-core cable.
132
Installation
Replacement U-bolt
In the event of connection to a two- or
three-phase supply, the installed U-bolt
must be replaced with the one supplied in
order to ensure correct fastening of the
cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid using adapters and shunts as these could
cause overheating and a risk of burns.
The values indicated refer to the
cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).