COMPLETING HEATER INSTALLATION
Step 3. Installing the Log Set and Burner Granules
For clarity the drawings are displayed without
showing the entire heater.
NOTE
DO NOT remove the burner from heater engine
to install the log set.
Use extreme care when handling the Log Set
components, they are made from a very fragile
high temperature material and will damage if
handled roughly. Only remove the components
from their packaging as required.
To achieve the correct location of the log set, hold the log set
at approximately 45°directly in front of the burner box
G
Maintain this angle and place the front feet
behind the unpainted inner horizontal steel lip
combust chamber.
Take care to ensure the ends of the log set DO
NOT touch the burner box panel walls
CAUTION
the insertion or positioning.
To set the log set into the final position within the burner box,
rotate the back of the log set down using the location of the
front feet
as pivot points until it is sitting flat on the rear
I
burner.
Confirm the correct location of the log set before
proceeding with the placement of the granular burner medium,
ensuring that the log set is firmly seated in the centre of the
burner box and not touching the side walls and that the ports
of both the front and rear burners are clean and clear of any
debris that may have been shed during the log set installation.
Installation of the granular burner medium may now begin, for
best flame effect carefully place, DO NOT POUR, the granular
burner medium over and around the front burner ports. It is
desirable that the gas jet is diffused by the granules, this will
reduce any 'candling' effect of the flame enhancing the realistic
log burning look of the heater.
DO NOT force any granular material into the
burner ports or completely block any of the
CAUTION
burner ports.
DO NOT place any of the granular burner
medium on the rear burner.
Step 4. Replacing the Burner Box Glass
Replace burner box glass panel assembly in reverse
sequence as instructed in Step 2. page 23.
Rinnai Australia
J
.
K
of the log set
I
of the
J
during
L
24
K
Approx' 45°
J
I
L
CAUTION
I
COVERING PORTS
Slimfire 252 Operation & Installation Manual
G
I

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slimfire 252Ribf25l

Table of Contents