Parameter Adjustment - Mitsubishi Electric FR-A8APS-02 Instruction Manual

Ssi communication function
Table of Contents

Advertisement

4.2

Parameter adjustment

The following shows the recommended setting values of the inverter parameters for each distance meter during SSI
communication.
The setting values in
• BPS307i
BPS307i
Item
Type
Laser (reading bar codes)
Clock frequency
80 to 800 kHz
SSI code type
Gray
Number of SSI data bits
25 bit
24 bit
Full resolution
(25 bit - 1 error bit)
Error bit
1 bit
Position resolution
1 mm
must be the same as the values shown in the table.
Description
1361
1362
1363
1365
1366
1367
1368
1369
1370
758
Inverter parameter setting value
Pr.
Setting value
0
0.2 (or 0.1)
1
25
24
1
1
0
0
0
Initial value
0
0.2
1
25
24
1
1
0
0
1
INVERTER SETTING
4
17

Advertisement

Table of Contents
loading

Table of Contents