Wiring - Mitsubishi Electric FR-A8APS-02 Instruction Manual

Ssi communication function
Table of Contents

Advertisement

2.3

Wiring

(1) Strip the signal wires from the encoder as shown below. If too much of the wire is stripped, a short circuit may occur with
neighboring wires. If not enough of wire is stripped, wires may become loose and fall out.
Twist the stripped end of wires to prevent them from fraying. Do not solder it.
Cable stripping length
Use appropriate crimp terminals (ferrules, blade terminals, etc.) for these terminal blocks as necessary.
When using the crimp terminal, make sure that the stranded wire do not come out of the terminal.
NOTE
• Crimp terminals commercially available (as of May 2017. The product may be changed without notice.)
Wire gauge
Terminal
2
screw size
(mm
)
0.3
M2
0.5
5 mm
Damaged
Crumpled tip
Ferrule part No.
With insulation sleeve
AI 0,34-6TQ
Al 0,5-6WH
Unstranded
wires
Wires are not inserted
into the sleeve
Without insulation sleeve
A 0,34-7
A 0,5-6
INSTALLATION AND WIRING
Crimping tool
Manufacturer
model No.
Phoenix Contact
CRIMPFOX 6
Co., Ltd.
2
11

Advertisement