NOTE
• When installing/removing the plug-in option, hold the sides of the option. Do not press on the parts on the option circuit
board. Stress applied to the parts by pressing, etc. may cause a failure.
• Be careful not to drop mounting screws during the installation or removal of the plug-in option.
• Only one option attached to the option connector with high priority can function at once if more than one option of the
same name are installed together on an inverter. Priority is given to option connectors in descending order (1 to 3),
and options having a lower priority do not function.
• When the inverter cannot recognize the option due to improper installation or any other reason or when a option fault
or SSI communication error occurs, the protective function (E.1 to E.4) is activated and the inverter cannot be
operated. An indication from E.1 to E.3 is displayed depending on the connector used (option connector 1 to 3).
Mounted position
Option connector 1
Option connector 2
Option connector 3
"E.4" is displayed when an error status is included in SSI communication data received from this option.
• When removing the plug-in option, remove the two screws on either side, and then pull it straight out. Pressure applied
to the option connector and to the option board may break the option.
10
INSTALLATION AND WIRING
Fault indication