10-3-4. Indoor unit fixing
1. Pass the pipe through the hole in the wall, and hook
the indoor unit on the installation plate at the upper
hooks.
2. Swing the indoor unit to right and left to confirm that
it is firmly hooked up on the installation plate.
3. While pressing the indoor unit onto the wall, hook it
at the lower part on the installation plate. Pull the
indoor unit toward you to confirm that it is firmly
hooked up on the installation plate.
2
Press indoor unit
to lower hook
• For detaching the indoor unit from the installation
plate, pull the indoor unit toward you while pushing
its bottom up at the specified parts.
Push
Push
Fig. 10-3-19
Hang indoor unit's
hook here
1
Installation plate
Fig. 10-3-18
Press
(unhook)
CAUTION
MOUNTING INDOOR UNIT TO THE INSTALLATION PLATE
• The lower part of indoor unit may float, due to the
condition of piping and installer cannot fix it to the
installation plate. In that case, use the screws
provided to fix the indoor unit with the installation
plate.
• Especially when the pipes are pulled out to the left
side, the indoor unit must be screwed to the
installation plate.
8
Screw
MOUNTING INDOOR UNIT TO THE INSTALLATION PLATE
• In case left side or right of indoor unit may float, the
provided screws should be used to fix the indoor
unit directly to the wall at the predetermined
position.
• In the case of block, brick, concrete or similar type
wall, determining the mount screw position on the
wall can be used symbol (►) on the main body of
indoor unit for drill hole to insert clip anchors for
appropriate mounting screw.
- 73 -
Installation
1
plate
Indoor unit
8
Screw
8
Screw
Mounting screw
Reference
symbol
Front panel
6