Download Print this page

Goodman HAMFK Instructions

High altitude сonversion kit for modulating furnace

Advertisement

Quick Links

HAMFK - HIGH ALTITUDE CONVERSION KIT FOR
34
MODULATING FURNACE
"
FURNACES EQUIPPED WITH WHITE-RODGERS 36J27 SERIES GAS VALVES
Figure 1 - 36J27 Modulating Gas Valve
APPLICATION
This kit is to be used for high altitude conversion of modu-
lating gas furnaces equipped with WHITE-RODGERS 36J27
SERIES GAS VALVES ONLY (Figure 1). This kit also contains
parts and instructions for conversion to L.P. This kit is not
applicable in Canada. Parts apply as shown in the table be-
low.
Above 7,000 Feet
Natural Gas
Orifices
B2589907 (#49)
IOG-7005
December 2018
DO NOT DISCARD - RETAIN THESE INSTRUCTIONS FOR FUTURE USE.
Propane Gas
Orifices
B2589908 (#56)
Table 1
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500 • Houston, TX 77056
© 2018 Goodman Manufacturing Company, L.P.
i
s a registered trademark of Maytag Corporation or its related companies and is used under license
to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
Required Tools for Conversion Kit
Q'ty
1
Needle-Nose Pliers
1
7/16" Box Wrench
1
1/4" Nut Driver
1
1/8" Flat Blade Screwdriver
Manometer to read inlet and outlet pressure of the
1
gas valve (minimum range: 0"- 20" W.C.)
Gas leak detection solution like a soap and water
solution. Always wipe the solution from the joints
when testing is completed.
Only personnel that have been trained to install, adjust, service
or repair (hereinafter, "service") the equipment specified in
this manual should service the equipment. The manufacturer
will not be responsible for any injury or property damage
arising from improper service or service procedures. If you
service this unit, you assume responsibility for any injury or
property damage which may result. In addition, in jurisdictions
that require one or more licenses to service the equipment
specified in this manual, only licensed personnel should service
the equipment. Improper installation, adjustment, servicing
or repair of the equipment specified in this manual, or
attempting to install, adjust, service or repair the equipment
specified in this manual without proper training may result in
product damage, property damage, personal injury or death.
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
Description
-
0140M00513-A

Advertisement

loading

Summary of Contents for Goodman HAMFK

  • Page 1 5151 San Felipe, Suite 500 • Houston, TX 77056 IOG-7005 © 2018 Goodman Manufacturing Company, L.P. December 2018 s a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
  • Page 2 HIGH ALTITUDE CONVERSION 1. Shut OFF gas supply at manual shutoff and turn OFF power to the furnace. 2. Remove access door. 3. Disconnect wiring from the gas valve. 4. Remove the gas manifold assembly by removing the four screws connecting it to the burner bracket. See Figure 2 below. 4 Screws Manifold Gas Valve...
  • Page 3 5. Turn OFF gas to the unit at the manual shutoff valve and disconnect manometer. Reinstall line pressure tap plug. The pressure tap must be leak checked after resealing. GAS SUPPLY PRESSURE RANGE GAS TYPE NATURAL 5" w.c. 10" w.c. L.P.
  • Page 4 That’s why we know. . .There’s No Better Quality. Visit our website at www.goodmanmfg.com or www.amana-hac.com for information on: • Parts • Products • Contractor Programs and Training • Warranties • Financing Options • Customer Services © 2018 Goodman Manufacturing Company, L.P.