3.6.7 MTS CIRCUIT
Measuring
Item
instrument
MTS INPUT
Remote
LEVEL
control unit
check
No.
Setting item
A01
IN LEVEL
MTS
Frequency
STEREO VCO
counter
Signal
generator
Remote
control unit
No.
Setting item
A02
FH MON
A03
ST VCO
MTS SAP
Frequency
VCO
counter
Signal
generator
Remote
control unit
No.
Setting item
A08
5FH MON
A09
SAP VCO
MTS FILTER
Remote
control unit
No.
Setting item
A04
PIL CAN
A05
FILTER
Test point
Adjustment part
[3.SOUND(A)]
A01 : IN LEVEL
Variable
Initial setting
range
value
0~63
036
R OUT
[3. SOUND(A)]
[AUDIO OUT]
A02 : FH MON
A03 : ST VCO
Variable
Initial setting
range
value
0 63
0
0 63
043
R OUT
[3. SOUND(A)]
[AUDIO OUT]
A08 : 5FH MON
A09 : SAP VCO
Variable
Initial setting
range
value
0 1
0
0 63
044
[3. SOUND(A)]
A04 : PILOT CAN
A05 : FILTER
Variable
Initial setting
range
value
0 1
0
0 63
035
Description
(1) Select the <A01>(IN LEVEL).
(2) Verify that the <A01> is set at its initial setting value.
(1) Receive the RF signal (no modulated sound signal)
from the antenna terminal.
(2) Select 3.SOUND(A).
(3) Select the <A02>(FH MON) and change the setting
value from 0 to 1.
(4) Connect the frequency counter to R OUT of the
AUDIO OUT.
(5) Select the <A03>(ST VCO).
(6) Set the initial setting value of the <A03>.
(7) Adjust the <A03> so that the frequency counter will
±
display 15.73kHz
0.1kHz.
(8) Select the <A02> of the SOUND mode, and reset the
setting value from 1 to 0.
(1) Receive the RF signal (non modulated sound signal)
from the antenna terminal.
(2) Select 3.SOUND(A).
(3) Select the <A08> (SFH MON) and reset the setting
value from 0 to 1.
(4) Connect the frequency counter to R out of the
AUDIO OUT.
(5) Select the <A09> (SAP VCO).
(6) Set the initial setting value of <A09>.
(7) Adjust the <A09> so that the frequency counter will
±
display 78.67kHz
0.5kHz.
(8) Select the <A08>, and reset the setting value from 1
to 0.
(1) Select 3.SOUND(A).
(2) Select the <A05> (FILTER).
(3) Select the <A04> (PILOT CAN) and reset the setting
value from 0 to 1.
(4) Verify that the <A05> is set at its initial setting value.