Cable Connections - HP ProLiant SL160z G6 Maintenance And Service Manual

Hide thumbs Also See for ProLiant SL160z G6:
Table of Contents

Advertisement

When folding a flat ribbon cable, never fold to a sharp crease. Sharp creases may damage the
wires.
Some flat ribbon cables come pre-folded. Never change the folds on these cables.
Do not sharply bend any cable. A sharp bend can break the internal wires.
Never bend a SATA data cable tighter than a 30 mm (1.18 in) radius.
Never crease a SATA data cable.
Do not rely on components like the drive cage, power supply, or system cover to push cables
down into the chassis.
Removing power supply cables from the system board connectors (J36) follow below steps:
Squeeze on the top of the retaining latch attached to the cable end of the connector.
1.
Grasp the cable end of the connector and pull it straight up.
2.
CAUTION: Always pull the connector - NEVER pull on the cable. Pulling on the cable could damage
the cable and result in a failed power supply.
Figure 3
Unplugging power cables

Cable Connections

The following table provides information about switching power supply cable connector labels.
Table 1
Power BP Cable connections
Cable
Main power cable
RPS cable
The following table provides the system board designators that various cables plug into. For more
detailed information about system board components, see system board components.
All manuals and user guides at all-guides.com
To
Node 12-pin power connector
System board Power Supply
Management Interface connector
Cable Designator
J36
J42
Removal and Replacement Procedures 30