Download Print this page

NCR 7409-K073 Kit Instructions

Pedestal door scanner

Advertisement

Quick Links

7409‐K073 
Pedestal Door Scanner 
Kit Instructions 
 
Issue A 

Advertisement

loading

Summary of Contents for NCR 7409-K073

  • Page 1 7409‐K073  Pedestal Door Scanner  Kit Instructions    Issue A ...
  • Page 2: Revision Record

    Revision Record Issue Date Remarks A  Aug 2010  First issue             ...
  • Page 3 Introduction This kit provides the components to add a Bar Code Scanner to the Front Door of a  7409‐K066 pedestal.  Split Loom Tubing (1/2”) Screw, M3 x 0.5 x 6mm, Phillips, Ft Hd (3) 497-0469862 006-8612557 Nut, 6-32 006-8611426 Pedestal Door Mount Scanner Bracket 795-0165400 5/16” Cable Clamp Miniscan MS 3207-1000R Scanner 006-8604575 006-8612581 Pedestal Door Scanner Fit Plate 795-0165700 MS3207 Scanner Cable 497-0469023...
  • Page 4: Installation Procedures

    Installation Procedures 1. Open the Pedestal Door.  2. Remove the Pedestal Door Scanner Blank from the Pedestal Door (4 hex nuts).  Pedestal Door Scanner Blank Hex Nuts 28738   3. Insert the Pedestal Door Scanner Fit Plate and the MS3207 Scanner in the door  opening. Secure the assembly from the back with hex nuts (4).  MS3207 Scanner Hex Nuts (4) Pedestal Door Scanner Fit Plate   28739...
  • Page 5 4. Connect the MS3207 Scanner Cable to the scanner.  5. Wrap the Split Loom Tubing around the cable where the cable passes the door  hinge. Secure the cable to the pedestal using Cable Clamps.  Split Loom Tubing 28741   6. Connect the other end of the cable to a USB port on the terminal. ...