Revision Record Issue Date Remarks A Aug 2010 First issue ...
Page 3
Introduction This kit provides the components to add a Bar Code Scanner to the Front Door of a 7409‐K066 pedestal. Split Loom Tubing (1/2”) Screw, M3 x 0.5 x 6mm, Phillips, Ft Hd (3) 497-0469862 006-8612557 Nut, 6-32 006-8611426 Pedestal Door Mount Scanner Bracket 795-0165400 5/16” Cable Clamp Miniscan MS 3207-1000R Scanner 006-8604575 006-8612581 Pedestal Door Scanner Fit Plate 795-0165700 MS3207 Scanner Cable 497-0469023...
Installation Procedures 1. Open the Pedestal Door. 2. Remove the Pedestal Door Scanner Blank from the Pedestal Door (4 hex nuts). Pedestal Door Scanner Blank Hex Nuts 28738 3. Insert the Pedestal Door Scanner Fit Plate and the MS3207 Scanner in the door opening. Secure the assembly from the back with hex nuts (4). MS3207 Scanner Hex Nuts (4) Pedestal Door Scanner Fit Plate 28739...
Page 5
4. Connect the MS3207 Scanner Cable to the scanner. 5. Wrap the Split Loom Tubing around the cable where the cable passes the door hinge. Secure the cable to the pedestal using Cable Clamps. Split Loom Tubing 28741 6. Connect the other end of the cable to a USB port on the terminal. ...