[MAIN UNIT]
REF
PARTS
NO.
NO.
R172
7030009820 S.RES RR0510P-681-D (680)
R173
7030009820 S.RES RR0510P-681-D (680)
R174
7030009820 S.RES RR0510P-681-D (680)
R175
7030005530 S.RES ERJ2GEJ 100 X (10)
R176
7030005090 S.RES ERJ2GEJ 104 X (100K)
R177
7030005090 S.RES ERJ2GEJ 104 X (100K)
R178
7030004980 S.RES ERJ2GEJ 101 X (100)
R179
7030004980 S.RES ERJ2GEJ 101 X (100)
R180
7030005050 S.RES ERJ2GEJ 103 X (10K)
R181
7030005050 S.RES ERJ2GEJ 103 X (10K)
R184
7030008280 S.RES ERJ2GEJ 271 X (270)
R185
7030010090 S.RES ERJ2GEJ 180 X (18)
R186
7030005120 S.RES ERJ2GEJ 102 X (1K)
R187
7030008010 S.RES ERJ2GEJ 123 X (12K)
R188
7410001150 S.ARR EXB28V471JX
R189
7030005090 S.RES ERJ2GEJ 104 X (100K)
R190
7030008010 S.RES ERJ2GEJ 123 X (12K)
R191
7030005000 S.RES ERJ2GEJ 471 X (470)
R192
7030005110 S.RES ERJ2GEJ 224 X (220K)
R193
7030008280 S.RES ERJ2GEJ 271 X (270)
R194
7030004980 S.RES ERJ2GEJ 101 X (100)
R195
7030005110 S.RES ERJ2GEJ 224 X (220K)
R196
7030009320 S.RES ERJ2GEJ 4R7 X (4.7)
R197
7030005050 S.RES ERJ2GEJ 103 X (10K)
R198
7030009320 S.RES ERJ2GEJ 4R7 X (4.7)
R199
7030005050 S.RES ERJ2GEJ 103 X (10K)
R200
7030004980 S.RES ERJ2GEJ 101 X (100)
R201
7030005090 S.RES ERJ2GEJ 104 X (100K)
R202
7030005160 S.RES ERJ2GEJ 105 X (1M)
R204
7030005050 S.RES ERJ2GEJ 103 X (10K)
R205
7030008010 S.RES ERJ2GEJ 123 X (12K)
R207
7030005090 S.RES ERJ2GEJ 104 X (100K)
R208
7030010040 S.RES ERJ2GEJ-JPW
R209
7030005000 S.RES ERJ2GEJ 471 X (470)
R212
7410001140 S.ARR EXB28V104JX
R213
7030005530 S.RES ERJ2GEJ 100 X (10)
R214
7030004980 S.RES ERJ2GEJ 101 X (100)
R215
7030010040 S.RES ERJ2GEJ-JPW
R216
7410001140 S.ARR EXB28V104JX
R217
7410001140 S.ARR EXB28V104JX
R218
7030005090 S.RES ERJ2GEJ 104 X (100K)
R220
7410001140 S.ARR EXB28V104JX
R222
7410001140 S.ARR EXB28V104JX
R223
7030005050 S.RES ERJ2GEJ 103 X (10K)
R224
7410001150 S.ARR EXB28V471JX
R225
7030005090 S.RES ERJ2GEJ 104 X (100K)
R226
7030005110 S.RES ERJ2GEJ 224 X (220K)
R227
7410001150 S.ARR EXB28V471JX
R230
7410001150 S.ARR EXB28V471JX
R231
7030005000 S.RES ERJ2GEJ 471 X (470)
R232
7410001150 S.ARR EXB28V471JX
R233
7030004980 S.RES ERJ2GEJ 101 X (100)
R234
7410001150 S.ARR EXB28V471JX
R235
7410001150 S.ARR EXB28V471JX
R236
7030005090 S.RES ERJ2GEJ 104 X (100K)
R237
7030005530 S.RES ERJ2GEJ 100 X (10)
R238
7410001150 S.ARR EXB28V471JX
R239
7410001150 S.ARR EXB28V471JX
R240
7030004980 S.RES ERJ2GEJ 101 X (100)
R241
7030004990 S.RES ERJ2GEJ 221 X (220)
R242
7030009320 S.RES ERJ2GEJ 4R7 X (4.7)
R243
7030005090 S.RES ERJ2GEJ 104 X (100K)
R244
7410001150 S.ARR EXB28V471JX
R245
7410001150 S.ARR EXB28V471JX
R246
7030005310 S.RES ERJ2GEJ 124 X (120K)
R247
7030005720 S.RES ERJ2GEJ 563 X (56K)
R249
7030008010 S.RES ERJ2GEJ 123 X (12K)
R250
7030004980 S.RES ERJ2GEJ 101 X (100)
R251
7030006610 S.RES ERJ2GEJ 394 X (390K)
R252
7030010040 S.RES ERJ2GEJ-JPW
R253
7030004970 S.RES ERJ2GEJ 470 X (47)
R255
7030005040 S.RES ERJ2GEJ 472 X (4.7K)
R256
7030005040 S.RES ERJ2GEJ 472 X (4.7K)
R257
7410001140 S.ARR EXB28V104JX
R259
7030005170 S.RES ERJ2GEJ 474 X (470K)
R260
7030007290 S.RES ERJ2GEJ 222 X (2.2K)
R261
7030005050 S.RES ERJ2GEJ 103 X (10K)
R262
7030005090 S.RES ERJ2GEJ 104 X (100K)
R263
7410001140 S.ARR EXB28V104JX
R264
7410001140 S.ARR EXB28V104JX
R265
7030010040 S.RES ERJ2GEJ-JPW
R267
7410001140 S.ARR EXB28V104JX
R268
7410001150 S.ARR EXB28V471JX
R269
7030004980 S.RES ERJ2GEJ 101 X (100)
R270
7030005050 S.RES ERJ2GEJ 103 X (10K)
R271
7030005090 S.RES ERJ2GEJ 104 X (100K)
R272
7410001150 S.ARR EXB28V471JX
R273
7410001150 S.ARR EXB28V471JX
R274
7030005090 S.RES ERJ2GEJ 104 X (100K)
R275
7030005060 S.RES ERJ2GEJ 333 X (33K)
R276
7030010040 S.RES ERJ2GEJ-JPW
R277
7030004980 S.RES ERJ2GEJ 101 X (100)
R278
7030005090 S.RES ERJ2GEJ 104 X (100K)
R279
7030007290 S.RES ERJ2GEJ 222 X (2.2K)
R280
7030004990 S.RES ERJ2GEJ 221 X (220)
R281
7410001150 S.ARR EXB28V471JX
R282
7030005090 S.RES ERJ2GEJ 104 X (100K)
R283
7030005100 S.RES ERJ2GEJ 154 X (150K)
R285
7030005050 S.RES ERJ2GEJ 103 X (10K)
R286
7030005080 S.RES ERJ2GEJ 823 X (82K)
R287
7410001140 S.ARR EXB28V104JX
R288
7030007340 S.RES ERJ2GEJ 153 X (15K)
R289
7030006070 S.RES ERJ12YJ101U (100)
R290
7030005050 S.RES ERJ2GEJ 103 X (10K)
R291
7030005040 S.RES ERJ2GEJ 472 X (4.7K)
DESCRIPTION
M.
LOCATION
B
B
97.2/53.7
B
42.1/113.8
B
B
100.6/56.8
B
44.9/115.6
B
100.6/55.9
B
44.9/114.7
T
B
B
63.2/119.1
B
62.3/117.5
T
39.2/50.7
T
41.5/55.9
T
48.5/41.1
T
55.6/39.5
T
43.1/55.9
B
43.5/112.2
B
44.4/112.2
B
59.6/116.8
B
B
B
T
40.5/50.6
B
T
67.6/57.5
B
43.1/123.1
B
T
41.4/48.6
T
54.7/39.5
T
36.5/57.9
B
B
46.2/120.7
T
67.6/56.5
T
52.3/41.1
T
41.4/47.7
B
B
T
17.3/52.4
T
B
61.4/138.5
T
15.2/50.7
T
B
61.4/137.6
T
30.4/53.1
B
61.4/139.4
B
39.9/72.7
T
42.9/28.9
T
28.6/50.9
B
58.2/139.4
T
25.9/49.4
B
58.2/135.8
T
42.5/25.7
T
24.2/47.6
B
132.4/82.7
B
49.4/138.8
T
45.7/28.9
T
22.4/45.8
B
134.7/86.7
B
49.4/134.3
B
48.4/138.8
B
47.4/138.8
T
39.7/25.8
T
20.2/42.4
B
45.6/136.6
B
48.4/140.4
B
135.6/88.4
B
133.8/90.1
B
49.4/142.5
B
B
136.5/90.1
B
52.4/142.5
B
137.7/90.1
T
14.5/45.7
B
57.1/142.5
B
108.8/25.3
T
52.5/25.2
T
51.9/22.8
T
T
B
87.1/43.5
T
T
45.7/31.8
B
143.2/94.7
B
T
23.8/26.7
T
17.9/32.3
T
17.9/35.1
B
T
93.1/55.7
B
87.1/44.4
T
T
13.9/65.6
T
102.4/90.1
T
141.3/127.7
T
21.3/31.8
T
37.8/20.3
T
144/124.4
T
101.6/79.5
B
40.8/72.7
T
49.7/27.7
T
139.5/122.5
B
86.9/117.5
T
138.6/122.5
T
137.6/127.7
[MAIN UNIT]
H/V
REF
PARTS
NO.
NO.
97.4/65
R292
7030005050 S.RES ERJ2GEJ 103 X (10K)
R293
7030004980 S.RES ERJ2GEJ 101 X (100)
R294
7030004980 S.RES ERJ2GEJ 101 X (100)
73.6/111
R295
7030005090 S.RES ERJ2GEJ 104 X (100K)
R296
7030000440 S.RES MCR10EZHJ 3.3K (332)
R297
7030000440 S.RES MCR10EZHJ 3.3K (332)
R298
7030000440 S.RES MCR10EZHJ 3.3K (332)
R299
7030004980 S.RES ERJ2GEJ 101 X (100)
37/108.3
R300
7030005530 S.RES ERJ2GEJ 100 X (10)
96.4/49
R301
7030008300 S.RES ERJ2GEJ 184 X (180K)
R302
7030005590 S.RES ERJ2GEJ 680 X (68)
R303
7410001150 S.ARR EXB28V471JX
R304
7030005050 S.RES ERJ2GEJ 103 X (10K)
R306
7520000260 S.POS PRF18BB471QB1RB
R308
7030005060 S.RES ERJ2GEJ 333 X (33K)
7030005060 S.RES ERJ2GEJ 333 X (33K)
7030005070 S.RES ERJ2GEJ 683 X (68K)
R309
7030005040 S.RES ERJ2GEJ 472 X (4.7K)
R310
7030005030 S.RES ERJ2GEJ 152 X (1.5K)
R311
7030008410 S.RES ERJ2GEJ 392 X (3.9K)
99.2/53
R312
7030005050 S.RES ERJ2GEJ 103 X (10K)
100.1/53
R313
7030005050 S.RES ERJ2GEJ 103 X (10K)
48/120.7
R314
7030007280 S.RES ERJ2GEJ 331 X (330)
R315
7030005700 S.RES ERJ2GEJ 274 X (270K)
103.7/62
R316
7030005050 S.RES ERJ2GEJ 103 X (10K)
R317
7030005010 S.RES ERJ2GEJ 681 X (680)
R318
7030003260 S.RES ERJ3GEYJ 330 V (33)
48/122.6
R320
7030005090 S.RES ERJ2GEJ 104 X (100K)
R321
7030003370 S.RES ERJ3GEYJ 271 V (270)
R322
7030005600 S.RES ERJ2GEJ 273 X (27K)
R324
7030005050 S.RES ERJ2GEJ 103 X (10K)
103.7/64
R325
7030005120 S.RES ERJ2GEJ 102 X (1K)
R326
7030005240 S.RES ERJ2GEJ 473 X (47K)
R327
7030000260 S.RES MCR10EZHJ 100 (101)
R328
7030000280 S.RES MCR10EZHJ 150 (151)
R331
7030004980 S.RES ERJ2GEJ 101 X (100)
98.9/64
R332
7030003370 S.RES ERJ3GEYJ 271 V (270)
100.9/62
R333
7030005600 S.RES ERJ2GEJ 273 X (27K)
R334
7030005651 S.RES ERA3YKD 304V (300K)
38.6/56
R335
7030005871 S.RES ERA3YKD 104V (100K)
R336
7030005110 S.RES ERJ2GEJ 224 X (220K)
R337
7030005110 S.RES ERJ2GEJ 224 X (220K)
36.1/56
R339
7030005090 S.RES ERJ2GEJ 104 X (100K)
R341
7030005050 S.RES ERJ2GEJ 103 X (10K)
R342
7030005090 S.RES ERJ2GEJ 104 X (100K)
R346
7410001150 S.ARR EXB28V471JX
R347
7030005000 S.RES ERJ2GEJ 471 X (470)
R348
7030000620 S.RES MCR10EZHJ 100 K (104)
R349
7030000620 S.RES MCR10EZHJ 100 K (104)
R350
7030003560 S.RES ERJ3GEYJ 103 V (10K)
R352
7030005040 S.RES ERJ2GEJ 472 X (4.7K)
R353
7030005240 S.RES ERJ2GEJ 473 X (47K)
R354
7030005700 S.RES ERJ2GEJ 274 X (270K)
R355
7030005090 S.RES ERJ2GEJ 104 X (100K)
R356
7030005050 S.RES ERJ2GEJ 103 X (10K)
R357
7030003560 S.RES ERJ3GEYJ 103 V (10K)
R362
7540000290 ABS
R364
7030005110 S.RES ERJ2GEJ 224 X (220K)
R365
7030005050 S.RES ERJ2GEJ 103 X (10K)
R366
7030007290 S.RES ERJ2GEJ 222 X (2.2K)
R367
7030004980 S.RES ERJ2GEJ 101 X (100)
R368
7030008300 S.RES ERJ2GEJ 184 X (180K)
R369
7030005230 S.RES ERJ2GEJ 334 X (330K)
R370
7030008280 S.RES ERJ2GEJ 271 X (270)
R371
7030010040 S.RES ERJ2GEJ-JPW
R372
7030005000 S.RES ERJ2GEJ 471 X (470)
R373
7030005050 S.RES ERJ2GEJ 103 X (10K)
R374
7030000140 S.RES MCR10EZHJ 10 (100)
R375
7030010040 S.RES ERJ2GEJ-JPW
132/86.7
R376
7030004980 S.RES ERJ2GEJ 101 X (100)
R378
7030005210 S.RES ERJ2GEJ 822 X (8.2K)
R379
7030005210 S.RES ERJ2GEJ 822 X (8.2K)
R380
7030007260 S.RES ERJ2GEJ 330 X (33)
R381
7030005570 S.RES ERJ2GEJ 820 X (82)
R424
7410001150 S.ARR EXB28V471JX
R425
7410001150 S.ARR EXB28V471JX
R426
7410001150 S.ARR EXB28V471JX
R427
7030005000 S.RES ERJ2GEJ 471 X (470)
46.2/20
R428
7410001140 S.ARR EXB28V104JX
50.2/24
R429
7410001140 S.ARR EXB28V104JX
R430
7410001140 S.ARR EXB28V104JX
15/42.5
R431
7410001150 S.ARR EXB28V471JX
R432
7410001140 S.ARR EXB28V104JX
R433
7410001150 S.ARR EXB28V471JX
36/136.6
R435
7410001140 S.ARR EXB28V104JX
R436
7410001140 S.ARR EXB28V104JX
R438
7410001140 S.ARR EXB28V104JX
R439
7030005090 S.RES ERJ2GEJ 104 X (100K)
36/137.5
R440
7030005090 S.RES ERJ2GEJ 104 X (100K)
R443
7030005000 S.RES ERJ2GEJ 471 X (470)
R444
7030005240 S.RES ERJ2GEJ 473 X (47K)
145/126
R445
7030005240 S.RES ERJ2GEJ 473 X (47K)
R446
7030005240 S.RES ERJ2GEJ 473 X (47K)
R447
7030005090 S.RES ERJ2GEJ 104 X (100K)
R448
7030005090 S.RES ERJ2GEJ 104 X (100K)
R449
7030005170 S.RES ERJ2GEJ 474 X (470K)
R450
7030005050 S.RES ERJ2GEJ 103 X (10K)
R453
7030005120 S.RES ERJ2GEJ 102 X (1K)
R454
7030005120 S.RES ERJ2GEJ 102 X (1K)
R455
7030005010 S.RES ERJ2GEJ 681 X (680)
R456
7030005120 S.RES ERJ2GEJ 102 X (1K)
R467
7030005240 S.RES ERJ2GEJ 473 X (47K)
R468
7410001140 S.ARR EXB28V104JX
R469
7030005090 S.RES ERJ2GEJ 104 X (100K)
R470
7030005090 S.RES ERJ2GEJ 104 X (100K)
M.=Mounted side (T: Mounted on the Top side, B: Mounted on the Bottom side)
3
DESCRIPTION
M.
T
B
B
T
T
T
T
B
T
B
B
T
B
B
[USA-01] T
[EXP-01]
[EUR-01]
T
T
T
T
T
T
B
T
B
B
T
B 119.6/141.7
B 121.5/143.4
B
B
T
B 119.7/132.8
B 139.3/144.3
T
B
B 137.7/131.9
T
T
T
T
T
B
B
T
T
B 147.2/150.9
B
B
T
B
T
T
T
B
ERZV10D220
T
T
T
T
T
T
T
T
T
T
T
T
B
B
B
B
B
T
T
T
T
T
T
T
T
T
T
B
B
B
B
B
T
B
B
B
T
T
T
T
T
B
B
B
B
B
B
T
S.=Surface mount
H/V
LOCATION
144/126
136.5/83.3
136.5/85
137.6/122.5
118.4/79.6
120.2/79.6
116.6/79.6
29.1/19.4
47.6/73.1
85.6/105.6
135.6/85
47.7/68.4
84.3/130
84.4/104.4
144/127.7
102.2/75.7
143.3/120.2
145/122.5
146.8/120.2
103.5/77.8
146/124.4
86/128.9
11.2/128.2
138.5/94.7
140.2/90.1
15/124.1
31.3/12
32.3/12
13.2/125.7
12/120
139.5/136
57.8/30.5
55.9/29.7
12/120.9
13.2/120.6
12/125.3
33.3/12
45.3/56.9
43.5/73.8
9.8/132.9
26/149.7
6.4/131
10.2/125.3
55.8/56.9
123.3/103
127.4/102.2
9.8/134.5
10.1/150.2
65.1/71.2
7.4/120.7
7/123.5
9.7/117.3
8.5/117.8
9.7/118.2
6.1/120.7
5/117.3
115.3/15.8
115.3/14
111.2/12.3
100.1/16.3
62.3/122.2
63.2/126.1
59.6/126.1
57.8/123.7
61.4/126.1
46.3/42.9
36.8/23
47.8/33.9
25.5/26.7
48/22.7
49.7/30.2
52.3/43.6
17.9/40.3
15.2/48.2
39.6/23
39.1/47.8
44.3/41.2
34.4/47.7
37.3/47.8
36.4/47.8
60.4/59.2
13.5/33.6
13.5/36.1
13.5/37.4
50.2/19.2
49.3/19.2
39.5/19.2
50.2/16.5
52.1/14.9
94.9/2.7
124.9/2.7
109.9/2.7
38/44.6
31.8/48.5
32.6/44.6
10.9/20.2