INSTALLATION

TO REMOVE EXISTING TOILET
Turn off the water supply. Flush the toilet, and use a
sponge to remove the remaining water from the tank
and bowl. Disconnect the supply shut-off valve (if
present), and remove the old tank and bowl.
Remove the old wax gasket from the closet flange with
a putty knife. Remove the old T-bolts and discard them.
NOTICE: If the new toilet is not installed immediately,
temporarily stuff a rag into the closet flange.
Install two new 5/16" diameter T-bolts into the closet
flange.
TO INSTALL SUPPLY SHUT-OFF VALVE
Install the supply shut-off valve so it is 9" above the
finished floor line, and 4-1/8" to the left of the closet
flange centerline.
The centerline of the supply shut-off valve outlet should
extend 3-5/8" from the finished wall. Install the supply
shut-off valve with the outlet vertical.
AC
116627-2-
T-Bolts
9"
12"
2
Closet Flange
Fig. #1
Closet Flange
Fig. #2
Supply Shut-Off
Valve
4-1/8"
Closet Flange
Centerline
Fig. #3
Kohler Co., Kohler, WI