Step 5 - Condensate Drains - Carrier 40MUAA Installation Instructions Manual

Residential air handler system sizes 18k to 60k
Hide thumbs Also See for 40MUAA:
Table of Contents

Advertisement

40MUAA: Installation Instructions

Step 5 - Condensate Drains

The drainpipe is used to drain water away from the unit. Improper
installation may cause unit and property damage.
CAUTION
• Insulate suction line to prevent condensation, which could lead
to water damage. Check the local codes.
• If the drainpipe is bent or installed incorrectly, water may leak
and cause a water-level switch malfunction.
• In HEAT mode, the outdoor unit may discharge water. Ensure
that the outdoor drain will not contribute to damage and
slippage.
• DO NOT pull the drainpipe forcefully. This could disconnect it.
NOTE: Installation requires adapting the locally sourced drain line
to a "3/4" NPT female pipe thread connection.
INDOOR DRAINPIPE INSTALLATION
1. Cover the drainpipe with insulation, as required, to prevent
condensation and leakage. These units operate with a positive
pressure at the drain connection and a drain trap is required. The trap
needs to be installed as close to the unit as possible. Ensure the top
of the trap is below the connection to the drain pan to allow complete
drainage of the pan.
Fig. 36 —Vertical Discharge
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig. 37 — Vertical Discharge
NOTE: Horizontal runs must also have a drain trap installed ahead
of the horizontal run to eliminate air trapping.
NOTES: When using an extended drainpipe, tighten the indoor
connection with an additional protection tube to prevent it from
pulling loose.
Hand tighten the plug(s) for drain holes that are unused.
Incorrect installation could cause water to flow back into the unit and
flood.
2. Use a 2.5in (65mm) core drill to drill a hole in the wall. Make sure
the hole is drilled at a slight downward angle, so that the outdoor end
of the hole is lower than the indoor end by about 0.5in (12mm). This
will ensure proper water drainage. Place the protective wall cuff in
the hole. This protects the edges of the hole and helps seal the hole
once the installation is complete.
NOTE: When drilling the hole, make sure to avoid wires, plumbing,
and other sensitive components.
3. Pass the drain hose through the wall hole. Make sure the water
drains to a safe location where it will not cause water damage or a
slipping hazard.
NOTE: The drainpipe outlet should be at least 2in(5cm) above the
ground. If it touches the ground, the unit may become blocked and
malfunction. If you discharge the water directly into a sewer, make
sure that the drain has a U or S pipe to catch odors that might
A220800
otherwise come back into the house. Follow the local plumbing codes.
16
Wall
Outdoor
Indoor
Fig. 38 —Drill hole
A220801
A220804

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents