Pioneer PDP-507CMX Service Manual page 139

Hide thumbs Also See for PDP-507CMX:
Table of Contents

Advertisement

5
Initial setting
After turning the unit on, enter Factory mode.
Display RST MASK 01 (white).
Voltage setting
Set VOL SUS to 137 (Vsus = 205 V).
VOL RST P: Set to the voltage indicated on the panel label.
(See the conversion table for the electronic VR.)
VOL OFFSET: Tentatively set to the voltage indicated on the
panel label. (See the conversion table for the electronic VR.)
Aging
Perform aging with the fully white screen for 30 minutes
5
6
1 Preparations
FAY
MKS S51
(To 2 )
PDP-507CMX
6
7
with command
PAV S00
VFQ S03
WBI S01
PGM S00
Note:
To prevent an error caused by the temperature
characteristics and to let the unit show its full properties
after letting it sit, perform aging for 30 minutes to raise
the panel temperature to a certain extent.
This ensures the accuracy of inspection and adjustment.
7
8
A
B
C
D
E
F