5 Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.8).
6 Press "A" or "B" until the LCD display shows the code P02,
indicating entry into "parameter P02" (Figure 9.10).
Figure 9 .10
7 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter P02 (Figure 9.11).
78 = Default
83 = Correct
Figure 9 .11
8 Press "A" and hold until the LCD display shows the code P09,
indicating entry into "parameter P09" (Figure 9.12).
Figure 9 .12
9 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter P09 (Figure 9.13).
03 = Default
01 = Correct
Figure 9 .13
10 Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.12).
11 Press "A" and hold until the LCD display shows the code
A01, indicating entry into "parameter A01" (Figure 9.14).
Figure 9 .14
12 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A01 (Figure 9.15).
00 = Natural gas (G20)
01 = Propane gas - LPG (G31)
MAIN ELECTRONIC CONTROL/IGNITION P.C.B.
RESET
bar
RESET
bar
RESET
bar
RESET
bar
RESET
bar
Figure 9 .15
13 Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.14).
14 Press "A" and hold until the LCD display shows the code
A02, indicating entry into "parameter A02" (Figure 9.16).
Figure 9 .16
15 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A02.
01 = high temperature (50/80°C)
02 = low temperature (25/55°C)
03 = full temperature set (25/85°C) (factory setting)
16 Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.16).
17 Press "A" and hold until the LCD display shows the code
A12, indicating entry into "parameter A12" (Figure 9.17).
Figure 9 .17
18 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A12 (Figure 9.18).
03 = Default
04 = Correct
Figure 9 .18
19 Press "A" (Figure 9.5) to confirm the value entered and return
to the list of parameters (Figure 9.17).
20 Press "A" and hold until the LCD display shows the code
A21, indicating entry into "parameter A21" (Figure 9.19).
RESET
bar
RESET
bar
RESET
bar
RESET
bar
- 23 -