Biasi M275V.2024 SM Service Manual page 13

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for M275V.2024 SM:
Table of Contents

Advertisement

Figure 4 .5
3 Press the "E" key to set "1 - -", e sucthen press "A" to confirm
the 1 and go to the next segment.
4 Press the "E" key to set "1 9 -", then press "A" to confirm the
9 and go to the next segment.
5 Press the "E" key to set "1 9 8", then press "A" to confirm the
8 and go back to the list of parameters
6 Press "A" and hold until the LCD display shows the code
A51, indicating entry into "parameter A51" (Figure 4.6).
Figure 4 .6
7 By using keys "D" or "E" (Figure 4.3) it is possible to modify
the value of parameter A51 from 1 to 52 weeks (52 = 1 year).
8 Press "A" or "B" (Figure 4.3) to confirm the value entered and
return to the list of parameters (Figure 4.6).
9 Press "B" and hold until the LCD display shows the code
A50, indicating entry into "parameter A50" (Figure 4.7).
Figure 4 .7
10 By using keys "D" or "E" (Figure 4.3) it is possible to modify
the value of parameter A51:
00 = maintenance period not activated
01 = maintenance period activated
11 Press "A" or "B" (Figure 4.3) to confirm the value entered and
return to the list of parameters (Figure 4.7).
12 Press the "F" key (Figure 4.3) to exit "programming mode".
FAULT FINDING
RESET
bar
RESET
bar
RESET
bar
- 13 -