Statuses And Sub-Statuses - Baxi 224 Combi 2 Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 224 Combi 2:
Table of Contents

Advertisement

Setting
Description
(read only)
AM016
Flow temperature
AM018
Return temperature
AM019
Actual water pressure in central heating system
AM024
Current output of the boiler
AM027
Outside temperature
AM036
Flue gas temperature
AM037
Status of the 3-way valve (0: Heating, 1: DHW)
AM040
Outgoing DHW temperature check
AM091
Season mode (0: winter, 3: summer)
AM101
Internal set point
BM000
DHW temperature
CM030
Current room temperature for zone
CM120
Current operating mode in the zone (0: Disabled, 1: Enabled)
CM190
Zone ambient set point
CM210
Outside temperature in the zone
CM280
Zone calculated set point
DM001
Temperature of the DHW tank
DM002
Outgoing DHW flow speed
DM005
Solar system DHW temperature
DM009
Primary operating mode (0: Programming, 1: Manual, 2: Antifreeze/Holiday)
DM019
DHW mode active (1: Comfort, 2: Low, 3: Holiday, 4: Antifreeze
DM029
DHW temperature set point
GM001
Actual fan RPM
GM002
Actual fan RPM setpoint
GM003
Flame detected (0: Not detected, 1: Detected)
GM004
Gas valve (0: Open, 1: Closed, 2: Off)
GM007
Start-up (0: Off, 1: On)
GM008
Actual flame current measured
GM012
Contact release signal X16 (0: No; 1: Yes)
GM013
Boiler shutdown signal input (0: Open, 1: Closed)
GM044
Reason for shutdown checked (0: None)
1. Heating Stoppage
2. DHW Stoppage
3. Awaiting burner ignition
4. Heating flow temperature above maximum value
5. Heating flow temperature above the starting value
6. Heat exchanger temperature above the starting value
7. Average heating flow temperature value above the starting value
8. Heating flow temperature above the setpoint value
9. Temperature difference between flow and return too great
10. Heating flow temperature above the shutdown value
11. Heat request before the minimum wait time between two consecutive requests
12. Shutdown caused by flame value being too low
13. Solar temperature above the shutdown value
9.4.1

Statuses and sub-statuses

The STATUS is the operating phase of the boiler at the moment
of display. To view the status, select the parameter AM012. The
SUB-STATUS is the instantaneous operation the boiler is
performing at the moment of display. To view the sub-status,
select the parameter AM014.
9 Settings
Value
°C
°C
bar
0/100%
°C
°C
0/1
°C
0/3
°C
°C
°C
0/1
°C
°C
°C
°C
l/min
°C
0/1/2
1/2/3/4
°C
rpm
rpm
0/1
0/1/2
0/1
μA
0/1
0/1
0/13
Combi 2
59