Settings; Accessing The Settings; List Of Parameters - Baxi 224 Combi 2 Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 224 Combi 2:
Table of Contents

Advertisement

9

Settings

9.1

Accessing the settings

Fig.62
Step 2
F1 F1 F1
F2
Fig.63
Step 3
F1 F1 F1
F2 F3 F4
9.2

List of parameters

Tab.26
Table of parameters
Name
Description
Operation of contact X15 (also see setting AP098)
1: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code H02.10)
2: Contact open —> Heating, domestic hot water dis­
AP001
abled (error code H02.09)
3: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code E02.13 with reset re­
quest)
Manual heating request enabled based on implemen­
tation of setting AP026
AP002
0: Disabled
1: Enabled
Notification of low pressure in the heating installation
AP006
[bar]
Hours of burner ignition before the maintenance noti­
AP009
fication with AP010=1
Enables/disables maintenance notifications:
0: No notification
AP010
1: Customised notification (depending on settings
AP009 and AP011)
To display/change the list of SERVICE settings, proceed as follows:
press the F3 key, the
turn the
turn until you reach the
press the F4 key to confirm;
if accessing the installer menu, use the
and confirm by pressing the F4 key
turn the
key to confirm;
F4
BO-0000230-14
modify the value of the setting using the
press F4 to confirm;
press F1 to exit.
To view/modify the list of settings, it is also possible to connect the
Bluetooth interface to the boiler via the connector X10. Then interface the
handset (SERVICE) to the boiler using the SERVICE TOOL software.
BO-0000230-9
symbol on the menu bar starts to flash;
knob until you reach the
symbol to access installer settings, then
knob until you reach the desired setting, then press the F4
Danger
FOR LOW TEMPERATURE HEATING INSTALLATIONS
MODIFY SETTING CP000 ACCORDING TO THE MAXIMUM
FLOW TEMPERATURE.
Important
The factory settings for certain settings may differ based on the
market the product is destined for.
Factory
Minimum
value
2
0
0.8
0.6
3000
0
0
9 Settings
symbol to access user settings,
knob to enter code 0012
knob;
Maximum Level
Installer
Installer
3.0
Installer
51,000
Installer
Installer
Combi 2
53