3. CONVERSION RULES FOR THE PROGRAM CONVERSION FUNCTION
3.4

Converting Application Instructions

The F
, F
, and F
1
1J
instructions, as shown in the table below, so they cannot be converted automatically.
Refer to the programming manuals in the list of relevant manuals in Appendix 2 and convert the
instructions to the FX series. If you need a programming manual, consult the store where you pur-
chased the product.
· Application instruction programming example for the F
Application instructions for F
Applicable model
*1
F
, F
F
1
1J
2
-
Yes
-
Yes
-
Yes
-
Yes
-
-
-
-
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
34
series and the FX series have different types and expressions for application
2
F670
, F
, and F
1
1J
2
Instruction
number
*2
F670
New F
2
Yes
K0
All input refresh
Yes
K1
Partial input refresh (8 units)
Yes
K2
All output refresh
Yes
K3
Partial output refresh (8 units)
Yes
K4
WDT refresh
Disable preset from set value regis-
Yes
K5
ter for T and C
Yes
K6
Subroutine start
Yes
K7
Subroutine call
Yes
K8
Return subroutine conditions
Yes
K9
Return subroutines
Reset M473 digit increment/decre-
Yes
K10
ment flag
Yes
K11
Reset C660 counter output contact
Yes
K12
Read external signals
Read RUN input terminal informa-
Yes
K13
tion
Yes
K14
Set M571 carry flag
Yes
K15
Reset M571 carry flag
Yes
K16
Set M572 zero flag
Yes
K17
Reset M572 zero flag
Yes
K18
Set M573 borrow flag
Yes
K19
Reset M573 borrow flag
Yes
K20
2 to 4 binary decoder
Yes
K21
3 to 8 binary decoder
Yes
K22
4 to 16 binary decoder
Yes
K23
4 to 2 binary encoder
Yes
K24
8 to 3 binary encoder
Yes
K25
16 to 4 binary encoder
, F
, and F
1
1J
K□
*1 Generic term for F
earlier than V2.1
*2 Generic term for F
V2.1 or later
programmable controllers
Name
series
2
series running on versions
2
series running on version
2
Application instruction (FNC number) and
function of the FX programmable controller
to be changed
REF (FNC 50)
REF (FNC 50)
REF (FNC 50)
REF (FNC 50)
WDT (FNC 07)
There is no instruction in the FX series that
corresponds to a directly related application
instruction. (Handled in the program)
Set the start of the subroutine program
using pointer P (label P).
CALL (FNC 01)
The FX series has no corresponding
instruction or function.
SRET (FNC 02)
RST
RST
Interruption I and high-speed counter
The FX series has no corresponding
instruction or function.
SET M8022
RST M8022
SET M8020
RST M8020
SET M8021
RST M8021
DECO (FNC 41)
DECO (FNC 41)
DECO (FNC 41)
ENCO (FNC 42)
ENCO (FNC 42)
ENCO (FNC 42)