2. OVERVIEW OF PROGRAM CONVERSION USING FX-20P-E
2.3

Program Conversion Operation

2.3.1

Turning on FX-20P-E + FX-20P-E-FKIT

This section describes the steps to attach FX-20P-FIM and FX-20P-MFA-E onto FX-20P-E and
launch it.
■ CAUTION
Do not touch the connecting part for the programmable controller of FX-20P-E, the special module,
the connecting part for the memory cassette, and the connecting part for FX-20P-E of the system
memory cassette. The internal electric circuit may become faulty due to static electricity. Turn off
the power of the programmable controller before connecting FX-20P-E to it.
(1) Attach FX-20P-FIM to FX-20P-E.
(a) Remove the cover from the special module connection part at the top of FX-20P-E.
(b) Connect FX-20P-FIM.
(c) Secure FX-20P-FIM onto FX-20P-E with a screw.
Locking screw
(2) Replace the system memory cassette of FX-20P-E for the FX series with FX-20P-MFA-E (sys-
tem memory cassette for the MELSEC-F series).
(a) Push down the anti-slip of the system memory cassette from
the back of FX-20P-E.
(b) Once there is a gap of approx. 1mm between the
system memory cassette and FX-20P-E, pull out
the system memory cassette in the direction indi-
cated by the arrow.
(c) Connect (attach) FX-20P-MFA-E.
■ CAUTION
Do not touch the connecting part of the system memory
cassette and FX-20P-E.
16
FX-20P-FIM
I M
P - F
- 2 0
F X
Module connector
FX-20P-E