FILTER INSTALLATION
Note air flow direction arrow on filter pack. Remove old filter pack and slide new
filter pack fully into the appropriate slot. Verify that the airflow arrow points toward
the fan.
The baffle filter is reusable and should be cleaned at least weekly. Change the
pre-filter and Hepa filter pack as indicated on the front panel. These filters
are disposable and cannot be reused. All filters are accessible through the
front service door.
Use only genuine Wells replacement parts and filters, call (800) 264-7827
or your authorized Wells service agent. Parts supplied by others will
void your warranty and may not provide safe operation.
BAFFLE FILTER and GREASE CUP INSTALLATION
1.
Install baffle filter from front.
retainer slot. Push up until the baffle filter bottom clears the
lower lip of the retainer, then lower the baffle filter into the bottom retainer.
2. Install GREASE CUP below the baffle filter underneath the unit aligned with the drain hose.
Note: Failure to install the GREASE CUP will allow grease and moisture from the BAFFLE FILTER to
drop onto floor surfaces, creating both a SAFETY HAZARD and a SLIP HAZARD.
The BAFFLE FILTERS, PRE-FILTERS and FILTER PACK actuate position switches when they are
properly positioned. The filters must be properly installed for the induction units contactor to be
energized.
The filter access door actuates a switch and must be closed for the unit to energize.
WARNING
SLIP AND FALL HAZARD
DO NOT operate any grease-producing cooking equipment unless the grease cup is properly installed.
Oil will drip onto floor creating a slipping hazard.
CAUTION
BURN HAZARD
DO NOT operate any cooking appliance unless the grease cup is installed. Moisture dripping onto hot
surfaces, oil or grease can cause splattering.
WARNING
CLEAN FILTERS
DO NOT attempt to wash the HEPA / charcoal filter pack or pre-filter. Water absorption will render
the filter unusable. Use of a wet or clogged filter will cause the ventilation system to shut down. Use
only clean Wells
Authorized Service Parts. Keep spare filter packs on hand to avoid disruptions.
®
Wells Parts Department (800) 678-6314.