System MIDI Settings (SYSTEM-MIDI)

Here you can make overall MIDI settings for the entire OCTAPAD.
1. Choose MENU
SYSTEM
Ú
The SYSTEM-MIDI screen appears.
[Knob 1] (SEL) selects
a parameter.
Parameter
Value
Global Channel
OFF, 1–16
AUTO
MIDI Sync
INT
MIDI
USB
Local Control
OFF, ON
MIDI In -> Out Thru
OFF, ON
USB -> MIDI-Out Thru
OFF
USB Driver
GENERIC
VENDER
Prog Change TX
OFF, ON
Prog Change RX
OFF, ON
Ctrl Change Tx
OFF, ON
Ctrl Change Rx
OFF, ON
Device ID
17–32
MIDI (p . 16) .
Ú
Explanation
Specifies the transmit/receive channel.
With the "OFF" setting, MIDI messages will not be transmitted.
Specifies how the OCTAPAD's phrase playback tempo will be synchronized.
When MIDI Clock messages (F8) are received at the MIDI IN connector or the USB MIDI connector, the
OCTAPAD will automatically detect them and synchronize to their tempo.
The OCTAPAD will synchronize to its own internal clock. MIDI Clock messages received from the MIDI IN
connector or USB MIDI connector will be ignored.
Operation will be the same as for AUTO, but MIDI Clock from the USB MIDI connector will be ignored.
Operation will be the same as for AUTO, but MIDI Clock from the MIDI IN connector will be ignored.
Turns the Local Control setting on/off.
Local Control is a setting used when you're recording your pad performance onto an external MIDI sequencer.
When you're recording and Local Control is "OFF, " the performance data produced when you hit a pad will not
be sent directly to the OCTAPAD's internal sound generator; it will be sent through your external sequencer.
If this is "ON, " data received at MIDI IN connector will be re-transmitted from MIDI OUT connector.
If this is "ON, " incoming MIDI messages will be re-transmitted without change from the MIDI OUT connector.
Specifies the USB driver mode.
If you change this setting, you must power-off the OCTAPAD and turn it back on again.
Choose this if you're using the standard USB driver provided by your computer.
Normally you'll use this mode.
Choose this if you're using the USB driver downloaded from the Roland website.
Specifies whether program change messages will be transmitted (ON) to an external MIDI device or not
transmitted (OFF).
If this is "ON, " when you switch kits on the OCTAPAD, the program number assigned to the newly selected kit
will be transmitted.
Specifies whether program change messages sent from an external MIDI device will be received (ON) or not
received (OFF).
If this is "ON, " the OCTAPAD will switch to the kit that corresponds to the received program number.
Specifies whether control change messages will be transmitted to an external MIDI device (ON) or not
transmitted (OFF).
Specifies whether control change messages sent from an external MIDI device will be received (ON) or not
received (OFF).
When transmitted or receiving system exclusive messages, set this to match the device ID numbers of the
two units.
[Knob 3] (–/+) edits the value.