Rheem 260 Litre Installation And Owner's Manual page 19

Gas heavy duty water heater 260 litre models
Hide thumbs Also See for 260 Litre:
Table of Contents

Advertisement

INSTALLATION
These conditions may result in either water at a temperature exceeding the
requirements of AS/NZS 3500.4 being delivered to the hot water outlets in the
ablution areas, or the device closing completely and not delivering water at all,
or the device failing. Under either condition, the operation and performance of
the device cannot be guaranteed.
Circulated Hot Water Flow and Return System – Gas Water Heater
REDUCING HEAT LOSSES
The cold water line to and the hot water line from the water heater must be
insulated in accordance with the requirements of AS/NZS 3500.4. The
insulation must be weatherproof and UV resistant if exposed.
ANODE TYPES
The correct anode type for the water supply being used must be fitted in the
water heater (refer to
"Water Supplies"
on page 38). The black anode is fitted
as standard.
Total Dissolved Solids in water supply to the water heater
Anode colour code
0 – 40 mg/L
Green
40 – 600 mg/L
Black
600 – 2500 mg/L
Blue
SADDLING - PIPE WORK
To prevent damage to the cylinder when attaching pipe clips or saddles to the
water heater jacket, we recommend the use of self-drilling screws with a
maximum length of 12 mm. Should pre drilling be required, extreme caution
must be observed when penetrating the jacket of the water heater.
Note: Damage to the cylinder as a result of saddling to the jacket will void
the warranty.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

620260630260