Rotation Number Of Compressor Limitation By Outdoor Temperature - Fujitsu ASUH18LMAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH18LMAS:
Table of Contents

Advertisement

1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
• Cooling/Dry mode
Model name
AOUH18LMAS1
AOUH24LMAS1

1-5. Rotation number of compressor limitation by outdoor temperature

K zone
107.6°F
(42°C)
J zone
100.4°F
(38°C)
I zone
87.8°F
(31°C)
H zone
69.8°F
(21°C)
G zone
55.4°F
(13°C)
F zone
44.6°F
(7°C)
E zone
35.6°F
(2°C)
D zone
23.0°F
(-5°C)
C zone
14.0°F
(-10°C)
B zone
5.0°F
(-15°C)
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
G zone
H zone
I zone
J zone
K zone
A zone
B zone
C zone
D zone
E zone
F zone
G zone
H zone
I zone
J zone
K zone
- (04-5) -
Limitation of compressor
frequency
55 rps
50 rps
36 rps
34 rps
30 rps
26 rps
19 rps
19 rps
21 rps
24 rps
29 rps
60 rps
55 rps
52 rps
45 rps
36 rps
28 rps
21 rps
19 rps
21 rps
24 rps
29 rps
1. Rotation number control of compressor