Various Control; Auto Restart; Manual Auto Operation - Fujitsu ASUH18LMAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH18LMAS:
Table of Contents

Advertisement

7. Various control

7-1. Auto restart

→hen the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time (set by wireless remote controller)
Airflow direction setting
Swing
ECONOM↔ operation
MIN. HEAT operation
Remote control setting
→LAN LED setting

7-2. MANUAL AUTO operation

→hen the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
→hen MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode
Fan mode
Timer mode
Setting temperature
Vertical airflow direction louver setting
Horizontal airflow direction louver setting
S→ING
ECONOM↔
Human sensor
7-1. Auto restart
Operation contents memorized when the power is interrupted
Continuous (no timer setting available)
According to memory position
- (04-23) -
Auto changeover
AUTO
75.2°F (24°C)
Standard
Off
Off
Off
7. Various control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asuh24lmasAouh18lmas1Aouh24lmas1

Table of Contents