Rotation Number Of Compressor Limitation By Outdoor Temperature - Fujitsu General ASHH30KMTB Service Manual

Wall mounted type
Table of Contents

Advertisement

1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
• Cooling/Dry mode
Model name
ASHH30KMTB
ASHH36KMTB

1-5. Rotation number of compressor limitation by outdoor temperature

K zone
52°C
J zone
50°C
I zone
46°C
H zone
31°C
G zone
21°C
F zone
13°C
E zone
7°C
D zone
2
°C
C zone
-5
°C
B zone
-10°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
G zone
H zone
I zone
J zone
K zone
- (04-4) -
Limitation of compressor
frequency
55 rps
52 rps
47 rps
39 rps
33 rps
25 rps
18 rps
20 rps
20 rps
21 rps
24 rps
1. Rotation number control of compressor